Stability of amlodipine besylate and atenolol in multi-component tablets of mono-layer and bi-layer types

被引:18
作者
Aryal, Sajjan [1 ,2 ]
Skalko-Basnet, Natasa [1 ]
机构
[1] Pokhara Univ, Sch Pharmaceut & Biomed Sci, Fac Sci & Technol, Pokhara, Nepal
[2] Quest Pharmaceut P Ltd, Chhata Pipara, Bara, Nepal
关键词
amlodipine; atenolol; mono-layer; bi-layer tablet; stability;
D O I
10.2478/v10007-008-0012-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Multi-drug tablets of amlodipine besylate and atenolol were prepared as either mono-layer (mixed matrix) or bi-layer tablets containing each drug in a separate layer by using similar excipients and processing. Each tablet batch was packed in strip and blister packs and kept under accelerated temperature and humidity conditions. The stability of two tablet and packaging types was compared by HPLC analysis after 0, 1, 3 and 4.5 months and expressed as the content of intact amlodipine and atenolol. The content of atenolol did not decline regardless of tablet and packaging type. Amlodipine content in bi-layer tablets decreased to about 95 and 88% when packed in strips and blisters, respectively. When prepared as mono-layer tablets, the content decreased to 72 and 32%, respectively. The study revealed that the bi-layer tablet formulation was more stable than the mono-layer type. Further, the stability was increased when the tablets were packed in aluminium strips as compared to PVC blisters.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 16 条
[1]   Amlodipine besylate-excipients interaction in solid dosage form [J].
Abdoh, A ;
Al-Omari, MM ;
Badwan, AA ;
Jaber, AMY .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2004, 9 (01) :15-24
[2]   Photodegradation studies on Atenolol by liquid chromatography [J].
Andrisano, V ;
Gotti, R ;
Leoni, A ;
Cavrini, V .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (04) :851-857
[3]   Simultaneous determination of atenolol and amlodipine in tablets by high-performance thin-layer chromatography [J].
Argekar, AP ;
Powar, SG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 21 (06) :1137-1142
[4]   Fixed-dose combinations improve medication compliance: A meta-analysis [J].
Bangalore, Sripal ;
Kamalakkannan, Gayathri ;
Parkar, Sanobar ;
Messerli, Franz H. .
AMERICAN JOURNAL OF MEDICINE, 2007, 120 (08) :713-719
[5]  
Barman RK, 2007, PAK J PHARM SCI, V20, P274
[6]   Validated reversed-phase HPLC method for the determination of atenolol in the presence of its major degradation product [J].
Ceresole, R. ;
Moyano, M. A. ;
Pizzorno, M. T. ;
Segall, A. I. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (20) :3008-3018
[7]   Stability indicating RP-HPLC method for simultaneous determination of atorvastatin and amlodipine from their combination drug products [J].
Chaudhari, Bharat Ganeshbhai ;
Patel, Natvarlal Manilal ;
Shah, Paresh Bhagvatiprasad .
CHEMICAL & PHARMACEUTICAL BULLETIN, 2007, 55 (02) :241-246
[8]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[9]   Chemometric determination of amiloride hydrochloride, atenolol, hydrochlorothiazide and timolol maleate in synthetic mixtures and pharmaceutical formulations [J].
Ferraro, MCF ;
Castellano, PM ;
Kaufman, TS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (02) :305-314
[10]  
*INT C HARM TECHN, 2003, Q1AR2 INT C HARM TEC