Effect of device models on the multiobjective optimal operation of CCHP microgrids considering shiftable loads

被引:32
作者
Cui, Qiong [1 ]
Ma, Peipei [1 ]
Huang, Lei [1 ]
Shu, Jie [1 ]
Luv, Jie [2 ]
Lu, Lin [3 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, Guangzhou 510640, Peoples R China
[2] China Nucl Power Design Co Ltd Shenzhen, Shenzhen 518100, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
关键词
CCHP microgrid; Shiftable loads; Partial load ratio model; Constant efficiency model; Multiple optimization objectives; Heat-to-electricity ratio; DEMAND-SIDE MANAGEMENT; AIR ENERGY-STORAGE; GAS-TURBINE; OPTIMAL-DESIGN; OPTIMIZATION MODEL; SYSTEM DRIVEN; STRATEGY; DISPATCH; SOLAR; PERFORMANCE;
D O I
10.1016/j.apenergy.2020.115369
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Based on the importance of device modelling for the optimal operation of combined cooling, heating and power (CCHP) microgrids and load shifting for the demand-side response, the partial load ratio (PLR) and constant efficiency (CE) models of the main devices on the system operation are studied. Nonlinear PLR models of gas turbines, boilers and chillers are constructed. A piecewise least squares linearization method is proposed. Shiftable load models of cooling, heating and electricity are established, and load shifting is carried out. System optimization models with multiple optimization objectives are constructed and solved by a CPLEX solver. To compare the effects of different equipment models on the optimal operation under load shifting, different targets and heat-to-electricity ratios are given. The results show that compared with the segment broken-line linearization and least squares linearization method, the proposed method reduces the standard error of the performance curve by at least 20.97% and 75.49%, respectively. With different optimization objectives, the positive advantage of load shifting is related to the heat-to-electricity ratio. Using different heat-to-electricity ratios, the sensitivity of the optimization results of the PLR models to the heat-to-electricity ratio is higher than that of the CE models. The optimal operational effect of load shifting on different objectives of the PLR model is significantly better than that of the CE model. The model selection of the gas turbine, heating recovery steam generator and electric chiller with either the PLR or CE model demonstrates a considerable impact on the system operational results.
引用
收藏
页数:19
相关论文
共 40 条
[1]   Energy, exergy, and economic evaluations of a CCHP system by using the internal combustion engines and gas turbine as prime movers [J].
Abbasi, Mohammad ;
Chahartaghi, Mahmood ;
Hashemian, Seyed Majid .
ENERGY CONVERSION AND MANAGEMENT, 2018, 173 :359-374
[2]   Optimal design, operation and analytical criteria for determining optimal operating modes of a CCHP with fired HRSG, boiler, electric chiller and absorption chiller [J].
Afzali, Sayyed Faridoddin ;
Mahalec, Vladimir .
ENERGY, 2017, 139 :1052-1065
[3]   Analyzing the optimal coordination of a residential micro-CHP system with a power sink [J].
Alahaivala, Antti ;
Hess, Tobias ;
Cao, Sunliang ;
Lehtonen, Matti .
APPLIED ENERGY, 2015, 149 :326-337
[4]   Optimal electrical and thermal energy management of a residential energy hub, integrating demand response and energy storage system [J].
Brahman, Faeze ;
Honarmand, Masoud ;
Jadid, Shahram .
ENERGY AND BUILDINGS, 2015, 90 :65-75
[5]   A conceptual model of a smart energy management system for a residential building equipped with CCHP system [J].
Farmani, Farid ;
Parvizimosaed, Mehdi ;
Monsef, Hassan ;
Rahimi-Kian, Ashkan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 :523-536
[6]   A novel hybrid algorithm for electricity price and load forecasting in smart grids with demand-side management [J].
Ghasemi, A. ;
Shayeghi, H. ;
Moradzadeh, M. ;
Nooshyar, M. .
APPLIED ENERGY, 2016, 177 :40-59
[7]   Residential CCHP microgrid with load aggregator: Operation mode, pricing strategy, and optimal dispatch [J].
Gu, Wei ;
Lu, Shuai ;
Wu, Zhi ;
Zhang, Xuesong ;
Zhou, Jinhui ;
Zhao, Bo ;
Wang, Jun .
APPLIED ENERGY, 2017, 205 :173-186
[8]   A probability constrained multi-objective optimization model for CCHP system operation decision support [J].
Hu, Mengqi ;
Cho, Heejin .
APPLIED ENERGY, 2014, 116 :230-242
[9]  
Hu WH, 2010, IEEE POW ENER SOC GE
[10]   Optimal short-term scheduling of a novel tri-generation system in the presence of demand response programs and battery storage system [J].
Jabari, F. ;
Nojavan, S. ;
Ivatloo, B. Mohammadi ;
Sharifian, M. B. Bannae .
ENERGY CONVERSION AND MANAGEMENT, 2016, 122 :95-108