Determination of Hg2+ and Cu2+ ions by dual-emissive Ag/Au nanocluster/carbon dots nanohybrids: Switching the selectivity by pH adjustment

被引:80
|
作者
Babaee, Elaheh [1 ]
Barati, Ali [1 ]
Gholivand, Mohammad Bagher [1 ]
Taherpour, Avat [1 ]
Zolfaghar, Narges [1 ]
Shamsipur, Mojtaba [1 ]
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
关键词
Nanohybrid probe; Bimetallic nanoclusters; Carbon dots; Ratiometric; Fluorescence; Detection of Hg2+ and Cu2+; pH control; FLUORESCENT METAL NANOCLUSTERS; GOLD NANOCLUSTERS; QUANTUM DOTS; CARBON DOTS; SILVER NANOCLUSTERS; SENSITIVE DETECTION; AU NANOCLUSTERS; COPPER IONS; MERCURY II; NANODOTS;
D O I
10.1016/j.jhazmat.2018.12.104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An innovative dual-emissive ratiometric nanohybrid probe comprised of red-emitting a (Ag/Au)@insulin nanoclusters (NCs) and blue-emitting carbon dots (CDs) was designed for sensitive and selective ratiometric determination of Hg2+ and Cu2+ ions. The fluorescence intensity of CDs (lambda(ex) = 340 nm; lambda(ex) = 420 nm) was unaffected in the presence of the metal ions tested, whereas the red emitting NCs (lambda(ex) = 340 nm; lambda(ex) = 640 nm) was strongly quenched by both Cu2+ and Hg2+ ions. Interestingly, the selectivity of the probe toward these two ions was simply switched by controlling the pH of probe solution without using any chelating agent. The probe selectively responded to Hg2+ ions at acidic condition (pH = 4.0), Cu2+ ions at basic condition (pH = 10.0), and He2+-Cu2+ mixtures at pHs within this range. The respective detection limitsfor determination of Cu2+ and Hg2+ ions at their specific pH conditions were estimated as 5 nM and 7 nM, over linear ranges of 20-600 nM and 20-2000 nM, respectively. The fabricated ratiometric probe also showed distinguished fluorescence color changes to visual detection of these ions. Finally, the probe was successfully applied to determination of Hg2+ and Cu2+ ions in tap and mineral water samples.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [31] Pyrene or rhodamine derivative-modified surfaces of electrospun nanofibrous chemosensors for colorimetric and fluorescent determination of Cu2+, Hg2+, and pH
    Cho, Chia-Jung
    Lu, Shih-Tung
    Kuo, Chi-Ching
    Liang, Fang-Cheng
    Chen, Bo-Yu
    Chu, Chien-Chia
    REACTIVE & FUNCTIONAL POLYMERS, 2016, 108 : 137 - 147
  • [32] A thio-urea based chromogenic and fluorogenic chemosensor for expeditious detection of Cu2+, Hg2+ and Ag+ ions in aqueous medium
    Manna, Amit Kumar
    Mondal, Jahangir
    Chandra, Rukmani
    Rout, Kalyani
    Patra, Goutam K.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2018, 356 : 477 - 488
  • [33] Rationally Designed Efficient Dual-Mode Colorimetric/Fluorescence Sensor Based on Carbon Dots for Detection of pH and Cu2+ Ions
    Wang, Liang
    Li, Ming
    Li, Weitao
    Han, Yu
    Liu, Yijian
    Li, Zhen
    Zhang, Baohua
    Pan, Dengyu
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (10): : 12668 - 12674
  • [34] INVESTIGATION OF THIOCARBAMIDE-SUBSTITUTED PHOSPHAZENE AND THEIR COMPLEX-COMPOUNDS WITH AG+, CU2+, HG2+ IONS BY SPECTROSCOPIC AND THERMOGRAPHIC METHODS
    BORTUN, AI
    BELYAKOV, VN
    ZHURNAL OBSHCHEI KHIMII, 1986, 56 (06): : 1209 - 1217
  • [35] Detection of Hg2+ and F- Ions by Using Fluorescence Switching of Quantum Dots in an Au-Cluster-CdTe QD Nanocomposite
    Paramanik, Bipattaran
    Bhattacharyya, Santanu
    Patra, Amitava
    CHEMISTRY-A EUROPEAN JOURNAL, 2013, 19 (19) : 5980 - 5987
  • [36] One-pot synthesis of highly fluorescent Fe2+-doped carbon dots for a dual-emissive nanohybrid for the detection of zinc ions and histidine
    Han, Bingyan
    Peng, Tingting
    Yu, Mingbo
    Chi, Chen
    Li, Ying
    Hu, Xixi
    He, Gaohong
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (16) : 13651 - 13659
  • [37] “Off-on” fluorescence probe based on green emissive carbon dots for the determination of Cu2+ ions and glyphosate and development of a smart sensing film for vegetable packaging
    Jiajie Wu
    Xiaoyong Chen
    Zeyu Zhang
    Jiamin Zhang
    Microchimica Acta, 2022, 189
  • [38] "Off-on" fluorescence probe based on green emissive carbon dots for the determination of Cu2+ ions and glyphosate and development of a smart sensing film for vegetable packaging
    Wu, Jiajie
    Chen, Xiaoyong
    Zhang, Zeyu
    Zhang, Jiamin
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [39] Cholesterol appended bis-1,2,3-triazoles as simple supramolecular gelators for the naked eye detection of Ag+, Cu2+ and Hg2+ ions
    Ghosh, Kumaresh
    Panja, Atanu
    Panja, Santanu
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (04) : 3476 - 3483
  • [40] Novel oligothiophene-phenylamine based Schiff base as a fluorescent chemosensor for the dual-channel detection of Hg2+ and Cu2+ with high sensitivity and selectivity
    Zhang, Shanshan
    Niu, Qingfen
    Lan, Linxin
    Li, Tianduo
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 793 - 800