Refractive Index Sensitivity Enchantment of a Fiber Filter by MZI Cascaded Sagnac Interferometer

被引:0
|
作者
Ojha, N. N. Subhashree [1 ]
Kumar, Ashish [1 ]
Kumar, Naveen [1 ]
机构
[1] Indian Inst Informat Technol Design & Mfg, Dept Phys, Chennai 600127, Tamil Nadu, India
关键词
sagnac interferometer; refractive index; sensitivity enhancement;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel technique to enhance the sensitivity of single-fiber (SF) MZI based refractive index sensor is presented. An indigenously fabricated SF-MZI has been placed in MZI cascaded Sagnac interferometer fiber loop and its sensitivity is enhanced from 20.24 nm per RIU to 40.92 nm per RIU over a relatively large range from 1.3344 RIU to 1.4532 RIU.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] A refractive index insensitive PbS fiber temperature sensor based on Sagnac interferometer
    Fu, Xinghu
    Zhang, Jiangpeng
    Wang, Siwen
    Fu, Guangwei
    Bi, Weihong
    OPTICAL COMMUNICATION AND OPTICAL FIBER SENSORS AND OPTICAL MEMORIES FOR BIG DATA STORAGE, 2016, 10158
  • [2] Cascaded fiber non-adiabatic taper and Sagnac loop for refractive index sensing
    Zhao, Yuanfang
    Jia, Zhaonian
    Dai, Maolin
    Zhao, Caiyue
    Gandhi, Manthangal Sivanesan Aruna
    Sun, Shuqing
    Li, Qian
    Fu, H. Y.
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332
  • [3] Controlling the sensitivity of a Non-adiabatic tapered optical fiber for measuring the refractive index using all fiber Sagnac loop Interferometer
    Zibaii, M. I.
    Jorge, P. A. S.
    Frazao, O.
    Latifi, H.
    INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS, 2011, 8001
  • [4] Refractive Index Sensor Based on Excessively Tilted Fiber Grating Sagnac Vernier Interferometer
    Gu Hong
    Luo Binbin
    Shi Shenghui
    Zou Xue
    Yang Xiangwen
    Li Yujie
    Chen Huiji
    Zhao Mingfu
    ACTA OPTICA SINICA, 2022, 42 (20)
  • [5] Refractive Index and Temperature Sensing with Sagnac-Mach Zehnder Hybrid Fiber Interferometer
    Li, Xuegang
    Nguyen, Linh, V
    Ebendorff-Heidepriem, Heike
    Zhang, Yanan
    Warren-Smith, Stephen C.
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 2483 - 2485
  • [6] Fiber laser cascaded with an MZ interferometer for simultaneous measurement of temperature and refractive index
    Li, Jingwen
    Hong, Tianjia
    Yu, Desheng
    Che, Kaijun
    Chen, Lujian
    APPLIED OPTICS, 2023, 62 (34) : 9119 - 9124
  • [7] Refractive index sensor of a photonic crystal fiber Sagnac interferometer based on variable polarization states
    Liu, Qiang
    Xin, Liang
    Wu, Zhaoxia
    APPLIED PHYSICS EXPRESS, 2019, 12 (06)
  • [8] Tunable dual-wavelength fiber laser based on an MMI filter in a cascaded Sagnac loop interferometer
    Ma, Lin
    Kang, Zexin
    Qi, Yanhui
    Jian, Shuisheng
    LASER PHYSICS, 2014, 24 (04)
  • [9] High-sensitivity refractive index and temperature sensor based on cascaded dual- wavelength fiber laser and SNHNS interferometer
    Yin, Bin
    Wu, Songhua
    Wang, Muguang
    Liu, Wenqi
    Li, Haisu
    Wu, Beilei
    Wang, Qichao
    OPTICS EXPRESS, 2019, 27 (01) : 252 - 264
  • [10] Cascaded ring resonator and Mach-Zehnder interferometer with a Sagnac loop for Vernier-effect refractive index sensing
    Troia, Benedetto
    De Leonardis, Francesco
    Passaro, Vittorio M. N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 76 - 89