Venous Saturation Slab Causes Overestimation of Stenosis Length in Two-Dimensional Time-of-Flight Magnetic Resonance Angiography

被引:2
作者
Wikstrom, J. [1 ]
Bjornerud, A. [2 ,3 ]
McGill, S. [1 ]
Johansson, L. [1 ]
机构
[1] Univ Uppsala Hosp, Dept Radiol, SE-75185 Uppsala, Sweden
[2] Radium Hosp Med Ctr, Rikshosp, Dept Phys Med, Oslo, Norway
[3] Univ Oslo, Dept Phys, Oslo, Norway
关键词
Flow; magnetic resonance angiography; phantom study; NEPHROGENIC SYSTEMIC FIBROSIS; SIGNAL LOSS; MR-ANGIOGRAPHY; IN-VITRO; PERIPHERAL ARTERIES; GADOLINIUM;
D O I
10.1080/02841850802562063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The use of downstream saturation slabs in two-dimensional time-of-flight magnetic resonance angiography (2D TOF MRA) of the arterial system eliminates signal from regions with countercurrent flow, as seen in veins, but possibly also beyond arterial stenoses because of flow turbulence. Purpose: To investigate the contribution of a downstream saturation slab to signal intensity (SI) loss beyond stenoses at 2D TOF MRA. Material and Methods: 2D TOF MRA was performed on a bifurcation phantom with a tight stenosis at 1.5T during pulsatile flow. Qualitative and quantitative evaluations of stenosis delineation were performed with different echo times (TE) (3.7 or 7.0 ms), spatial resolution (1x1x1 or 1x1x5 mm3), and with or without a downstream saturation slab. For reference, a high-resolution contrast-enhanced sequence without flow was obtained. Results: The downstream saturation slab caused severe signal loss immediately distal to the stenosis, causing overestimation of stenosis length. This region corresponded with a region of poststenotic flow jet, where turbulence is expected. With increase in TE, there was some increased SI loss at the level of maximum stenosis. A lower spatial resolution resulted in overall poorer delineation of the stenosis. Conclusion: Using clinically relevant sequence parameters, the use of a downstream saturation slab at 2D TOF MRA was found to be a major contributor to signal loss in stenotic regions, which can result in an overestimation of stenosis length.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 14 条
  • [1] FURST G, 1995, J COMPUT ASSIST TOMO, V19, P692, DOI 10.1097/00004728-199509000-00002
  • [2] MECHANISMS OF SIGNAL LOSS IN MAGNETIC-RESONANCE-IMAGING OF STENOSES
    GATENBY, JC
    MCCAULEY, TR
    GORE, JC
    [J]. MEDICAL PHYSICS, 1993, 20 (04) : 1049 - 1057
  • [3] Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis
    High, Whitney A.
    Ayers, Reed A.
    Chandler, John
    Zito, Gary
    Cowper, Shawn E.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2007, 56 (01) : 21 - 26
  • [4] Optimizing three-dimensional gadolinium-enhanced magnetic resonance angiography - Original investigation
    Maki, JH
    Prince, MR
    Chenevert, TC
    [J]. INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 528 - 537
  • [5] Magnetic resonance angiography of the peripheral arteries: current status
    Meaney, JFM
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (04) : 836 - 852
  • [6] In vitro model of arterial stenosis: Correlation of MR signal dephasing and trans-stenotic pressure gradients
    Mustert, BR
    Williams, DM
    Prince, MR
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (03) : 301 - 310
  • [7] TURBULENT FLUCTUATION VELOCITY - THE MOST SIGNIFICANT DETERMINANT OF SIGNAL LOSS IN STENOTIC VESSELS
    OSHINSKI, JN
    KU, DN
    PETTIGREW, RI
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 193 - 199
  • [8] MR angiography of internal carotid arteries: Breath-hold Gd-enhanced 3D fast imaging with steady-state precession versus unenhanced 2D and 3D time-of-flight techniques
    Sardanelli, F
    Zandrino, F
    Parodi, RC
    De Caro, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 208 - 215
  • [9] IN-VITRO ASSESSMENT OF THE BEHAVIOR OF MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PRESENCE OF CONSTRICTIONS
    SEBOK, NR
    SEBOK, DA
    WILKERSON, D
    MEZRICH, RS
    ZATINA, M
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (07) : 604 - 610
  • [10] ILIAC ARTERY NIR ANGIOGRAPHY - COMPARISON OF 3-DIMENSIONAL GADOLINIUM-ENHANCED AND 2-DIMENSIONAL TIME-OF-FLIGHT TECHNIQUES
    SNIDOW, JJ
    AISEN, AM
    HARRIS, VJ
    TREROTOLA, SO
    JOHNSON, MS
    SAWCHUK, AP
    DALSING, MC
    [J]. RADIOLOGY, 1995, 196 (02) : 371 - 378