Novel Multiplex Bead-Based Assay for Detection of IDH1 and IDH2 Mutations in Myeloid Malignancies

被引:5
作者
Shivarov, Velizar [1 ]
Ivanova, Milena [2 ]
Hadjiev, Evgueniy [3 ]
Naumova, Elissaveta [2 ]
机构
[1] Natl Hematol Hosp, Lab Hematopathol & Immunol, Sofia, Bulgaria
[2] Med Univ, Alexandrovska Univ Hosp, Dept Clin Immunol, Sofia, Bulgaria
[3] Med Univ, Alexandrovska Univ Hosp, Dept Clin Hematol, Sofia, Bulgaria
来源
PLOS ONE | 2013年 / 8卷 / 09期
关键词
LEUKEMIA; PCR; IMMUNOHISTOCHEMISTRY; PERFORMANCE; TECHNOLOGY; GENE; AML;
D O I
10.1371/journal.pone.0076944
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Isocitrate dehydrogenase 1 and 2 (IDH) mutations are frequently found in various cancer types such as gliomas, chondrosarcomas and myeloid malignancies. Their molecular detection has recently gained wide recognition in the diagnosis and prognosis of these neoplasms. For that purpose various molecular approaches have been used but a universally accepted method is still lacking. In this study we aimed to develop a novel bead-based liquid assay using Locked nucleic acids (LNA)-modified oligonucleotide probes for multiplexed detection of the most frequent IDH1 (p.R132C, p.R132G, p.R132H, p.R132L, p.R132S) and IDH2 (p.R140Q, p.R172K) mutations. The method includes four steps: 1) PCR amplification of the targeted fragments with biotinylated primers; 2) Direct hybridization to barcoded microbeads with specific LNA-modified oligonucleotide probes; 3) Incubation with phycoerythrin coupled streptavidin; 4) Acquisition of fluorescent intensities of each set of beads on a flow platform (LuminexCorp., USA). We tested the performance of the assay on both artificial plasmid constructs and on clinical samples from 114 patients with known or suspected myeloid malignancies. The method appeared to be superior to direct sequencing having a much higher sensitivity of 2.5% mutant alleles. Applying this method to patients' samples we identified a total of 9 mutations (one IDH1 p.R132C, seven IDH2 p.R140Q and one IDH2 p.R172K). In conclusion, this method could be successfully implemented in the diagnostic work-up for various tumors known to harbor IDH1/2 mutations (e. g. myeloid malignancies, gliomas, etc.). International initiatives are needed to validate the different existing methods for detection of IDH1/2 mutations in clinical settings.
引用
收藏
页数:6
相关论文
共 34 条
  • [1] Comparative study of IDH1 mutations in gliomas by immunohistochemistry and DNA sequencing
    Agarwal, Shipra
    Sharma, Mehar Chand
    Jha, Prerana
    Pathak, Pankaj
    Suri, Vaishali
    Sarkar, Chitra
    Chosdol, Kunzang
    Suri, Ashish
    Kale, Shashank Sharad
    Mahapatra, Ashok Kumar
    Jha, Pankaj
    [J]. NEURO-ONCOLOGY, 2013, 15 (06) : 718 - 726
  • [2] COLD PCR HRM: A Highly Sensitive Detection Method for IDH1 Mutations
    Boisselier, Blandine
    Marie, Yannick
    Labussiere, Marianne
    Ciccarino, Pietro
    Desestret, Virginie
    Wang, XiaoWei
    Capelle, Laurent
    Delattre, Jean-Yves
    Sanson, Marc
    [J]. HUMAN MUTATION, 2010, 31 (12) : 1360 - 1365
  • [3] Bujko M, 2010, MOL DIAGN THER, V14, P163, DOI 10.2165/11537170-000000000-00000
  • [4] A single-tube, sensitive multiplex method for screening of isocitrate dehydrogenase 1 (IDH1) mutations
    Chou, Wen-Chien
    Huang, Yen-Ning
    Huang, Chi-Fei
    Tseng, Mei-Hsuan
    Tien, Hwei-Fang
    [J]. BLOOD, 2010, 116 (03) : 495 - 496
  • [5] Applications of Luminex® xMAP™ technology for rapid, high-throughput multiplexed nucleic acid detection
    Dunbar, SA
    [J]. CLINICA CHIMICA ACTA, 2006, 363 (1-2) : 71 - 82
  • [6] An introduction to ROC analysis
    Fawcett, Tom
    [J]. PATTERN RECOGNITION LETTERS, 2006, 27 (08) : 861 - 874
  • [7] Performance and Clinical Evaluation of a Sensitive Multiplex Assay for the Rapid Detection of Common NPM1 Mutations
    Hafez, Michael
    Ye, Fei
    Jackson, Keith
    Yang, Zhe
    Karp, Judith E.
    Labourier, Emmanuel
    Gocke, Christopher D.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2010, 12 (05) : 629 - 635
  • [8] Prognostic implications of the IDH1 synonymous SNP rs11554137 in pediatric and adult AML: a report from the Children's Oncology Group and SWOG
    Ho, Phoenix A.
    Kopecky, Kenneth J.
    Alonzo, Todd A.
    Gerbing, Robert B.
    Miller, Kristen L.
    Kuhn, Julia
    Zeng, Rong
    Ries, Rhonda E.
    Raimondi, Susana C.
    Hirsch, Betsy A.
    Oehler, Vivian
    Hurwitz, Craig A.
    Franklin, Janet L.
    Gamis, Alan S.
    Petersdorf, Stephen H.
    Anderson, Jeanne E.
    Godwin, John E.
    Reaman, Gregory H.
    Willman, Cheryl L.
    Bernstein, Irwin D.
    Radich, Jerald P.
    Appelbaum, Frederick R.
    Stirewalt, Derek L.
    Meshinchi, Soheil
    [J]. BLOOD, 2011, 118 (17) : 4561 - 4566
  • [9] Rapid Screening of ASXL1, IDH1, IDH2, and c-CBL Mutations in de Novo Acute Myeloid Leukemia by High-Resolution Melting
    Ibanez, Mariam
    Such, Esperanza
    Cervera, Jose
    Luna, Irene
    Gomez-Segui, Ines
    Lopez-Pavia, Maria
    Dolz, Sandra
    Barragan, Eva
    Fuster, Oscar
    Llop, Marta
    Rodriguez-Veiga, Rebeca
    Avaria, Amparo
    Oltra, Silvestre
    Senent, M. Leonor
    Moscardo, Federico
    Montesinos, Pau
    Martinez-Cuadron, David
    Martin, Guillermo
    Sanz, Miguel A.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06) : 594 - 601
  • [10] Novel multiplex bead-based assay with LNA-modified probes for detection of MPL exon 10 mutations
    Ivanova, Milena I.
    Shivarov, Velizar S.
    Hadjiev, Evgueniy A.
    Naumova, Elissaveta J.
    [J]. LEUKEMIA RESEARCH, 2011, 35 (08) : 1120 - 1123