Chromium speciation in the blood of metal-on-metal hip implant patients

被引:5
|
作者
Finley, Brent [1 ]
Scott, Paul K. [2 ]
Glynn, Meghan E. [3 ]
Paustenbach, Dennis [4 ]
Donovan, Ellen [4 ]
Thuett, Kerry A. [4 ]
机构
[1] Cardno ChemRisk, Brooklyn, NY USA
[2] Cardno ChemRisk, Pittsburgh, PA USA
[3] Cardno ChemRisk, Chicago, IL USA
[4] Cardno ChemRisk, San Francisco, CA 94105 USA
来源
TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY | 2017年 / 99卷 / 01期
关键词
Chromium; Cr(III); Cr(VI); hip implant; analytical chemistry; RBC; metal-on-metal; ION LEVELS; RESURFACING ARTHROPLASTY; HEXAVALENT CHROMIUM; CORROSION PRODUCTS; BEARING SURFACES; STAINLESS-STEEL; SYNOVIAL-FLUID; DRINKING-WATER; TRACE-ELEMENTS; WEAR PARTICLES;
D O I
10.1080/02772248.2016.1148904
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to determine the valence state of chromium (Cr) in the blood of individuals with Cr-containing metal hip implants. Serum and red blood cell (RBC) Cr concentrations from 52 patients with Cr-containing total hip arthroplasties were measured preoperatively and at 3, 12, and 24 months postoperatively. Geometric mean and median pre-surgery serum Cr concentrations were consistently below 0.2 mu g/L, while geometric mean and median pre-op RBC Cr concentrations were typically about four-to six-fold higher than the serum values. A significant 5- to 13-fold increase was found in the mean and median serum Cr concentrations three months post-surgery, with an 8- to 18-fold rise at 12 and 24 months, respectively. Steady-state serum concentrations were reached between 3 and 12 months. In contrast, there were no marked differences in mean and median RBC Cr concentrations pre- and post-surgery. Slope regression analysis for our data was similar to those reported for Cr(III) in spiked blood samples. The analysis showed that Cr released from hip implants preferentially distributed into serum and not RBC, indicating that the form of Cr present in blood of hip implant patients was in the form of non-toxic Cr(III). Our findings indicate that blood Cr concentrations Cr(III) associated with metal implants do not pose an adverse health risk to patients, which is in agreement with findings published by most investigators.
引用
收藏
页码:48 / 64
页数:17
相关论文
共 50 条
  • [21] Osteolysis in patients with a metal-on-metal hip arthroplasty
    Carr, Ashley M.
    Desteiger, Richard
    ANZ JOURNAL OF SURGERY, 2008, 78 (03) : 144 - 147
  • [22] Early Markers of Nephrotoxicity in Patients With Metal-on-metal Hip Arthroplasty
    Corradi, Massimo
    Daniel, Joseph
    Ziaee, Hena
    Alinovi, Rossella
    Mutti, Antonio
    McMinn, Derek J. W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) : 1651 - 1659
  • [23] The painful metal-on-metal hip resurfacing
    Hart, A. J.
    Sabah, S.
    Henckel, J.
    Lewis, A.
    Cobb, J.
    Sampson, B.
    Mitchell, A.
    Skinner, J. A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 738 - 744
  • [24] Implant failure in bilateral metal-on-metal hip resurfacing arthroplasties: a clinical and pathological study
    Uchihara, Yoshinubo
    Grammatopoulos, George
    Munemoto, Mitsuru
    Matharu, Gulraj
    Inagaki, Yusuke
    Pandit, Hemant
    Tanaka, Yasuhito
    Athanasou, Nick A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2018, 29 (03)
  • [25] Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants
    Sampson, Barry
    Hart, Alister
    ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 118 - 131
  • [26] No need for immediate freezing of metal ion blood samples in patients with metal-on-metal hip articulations
    Lindberg-Larsen, Martin
    Penny, Jeannette Ostergaard
    DANISH MEDICAL JOURNAL, 2012, 59 (12):
  • [27] Blood metal ion concentrations in metal-on-metal total hip arthroplasty
    Ohtsuru T.
    Morita Y.
    Murata Y.
    Shimamoto S.
    Munakata Y.
    Kato Y.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 527 - 532
  • [28] False profile view is independently associated with serum metal levels in patients with metal-on-metal hip arthroplasty
    Larsen, Bo Madvig
    Borgwardt, Arne
    Ribel-Madsen, Soren
    Zerahn, Bo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (06): : 1029 - 1036
  • [29] Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses A Prospective Cohort Study to Investigate the Relationship Between Blood Metal Ion Levels and Implant Failure
    Hart, A. J.
    Sabah, S. A.
    Sampson, B.
    Skinner, J. A.
    Powell, J. J.
    Palla, L.
    Pajamaki, K. J. J.
    Puolakka, T.
    Reito, A.
    Eskelinen, A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (13): : 1091 - 1099
  • [30] Metal-on-Metal Hip Resurfacing
    Quesada, Mario J.
    Marker, David R.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 69 - 73