In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

被引:16
|
作者
Han, Gaofeng [1 ,2 ]
Li, Jing [1 ,2 ]
Wang, Shuo [1 ,2 ]
Liu, Yan [1 ,2 ]
Wang, Xuedong [1 ,2 ]
Zhou, Yanheng [1 ,2 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Orthodont, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[2] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
基金
对外科技合作项目(国际科技项目); 中国国家自然科学基金;
关键词
Computed tomography; Digital models; Tooth movement; Orthodontic reatment; CT; INTEGRATION; MAXILLARY; IMAGES;
D O I
10.4041/kjod.2019.49.2.97
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter-and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.
引用
收藏
页码:97 / 105
页数:9
相关论文
共 50 条
  • [1] Accuracy and reliability of landmark-based, surface-based and voxel-based 3D cone-beam computed tomography superimposition methods
    Ghoneima, A.
    Cho, H.
    Farouk, K.
    Kula, K.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2017, 20 (04) : 227 - 236
  • [2] Cranial Base Superimposition of Cone-Beam Computed Tomography Images: A Voxel-Based Protocol Validation
    Haas Junior, Orion Luiz
    Guijarro-Martinez, Raquel
    de Sousa Gil, Ariane Paredes
    Mendez-Manjon, Irene
    Valls-Otanon, Adaia
    Belle de Oliveira, Rogerio
    Hernandez-Alfaro, Federico
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (06) : 1809 - 1814
  • [3] A comparison of voxel- and surface-based cone-beam computed tomography mandibular superimposition in adult orthodontic patients
    Han, Gaofeng
    Li, Jing
    Wang, Shuo
    Wang, Linchuan
    Zhou, Yanheng
    Liu, Yan
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (01)
  • [4] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [5] Linear measurements of sinus floor elevation based on voxel-based superimposition of cone beam computed tomography images
    Huang, Jie
    Hu, Jiahui
    Luo, Rongchun
    Xie, Sisi
    Wang, Zuolin
    Ye, Ying
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1048 - 1053
  • [7] Voxel-based superimposition of serial craniofacial cone-beam computed tomographies for facial soft tissue assessment: Reproducibility and segmentation effects
    Kanavakis, Georgios
    Haener, Simeon T.
    Matthey, Francois
    Gkantidis, Nikolaos
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 159 (03) : 343 - +
  • [8] A Novel Method to Combine Maxilla-Based Coordinate System and Mandibular Voxel-Based Superimposition with Cone-Bean Computed Tomography
    Zhang, Chenghao
    Ji, Ling
    Li, Yijun
    Pan, Fangwei
    Liao, Wen
    Zhao, Zhihe
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [9] Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography
    Ye, Niansong
    Jian, Fan
    Xue, Junjie
    Wang, Sheng
    Liao, Lina
    Huang, Wenya
    Yang, Xing
    Zhou, Yang
    Lai, Wenli
    Li, Jingtao
    Wang, Jing
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (06) : 879 - 887
  • [10] Accuracy of Linear Measurements and Visibility of the Mandibular Canal of Cone-Beam Computed Tomography Images With Different Voxel Sizes: An In Vitro Study
    Waltrick, Karen Borges
    Nunes de Abreu Junior, Murillo Jose
    Correa, Marcio
    Zastrow, Michella Dinah
    Dutra, Vinicius D'Avila
    JOURNAL OF PERIODONTOLOGY, 2013, 84 (01) : 68 - 77