Influence of Continuous or Reciprocating Motion on Cyclic Fatigue Resistance of 4 Different Nickel-Titanium Rotary Instruments

被引:151
作者
Pedulla, Eugenio [1 ]
Grande, Nicola M. [2 ]
Plotino, Gianluca [2 ]
Gambarini, Gianluca [2 ]
Rapisarda, Ernesto [1 ]
机构
[1] Univ Catania, Dept Surg, Catania, Italy
[2] Univ Roma La Sapienza, Dept Endodont, Rome, Italy
关键词
Continuous rotation; cyclic fatigue; M-wire; nickel-titanium; reciprocating motion; CONTINUOUS ROTATION; FILES; MOVEMENT; FRACTURE; CANALS; TORQUE; LIFE;
D O I
10.1016/j.joen.2012.10.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the resistance to flexural fatigue of Reciproc R25 (VDW, Munich, Germany), Wave One Primary (VDW, Munich, Germany), Mtwo (Sweden & Martina, Padova, Italy), and Twisted File (TF; SybronEndo, Orange, CA) instruments used in continuous rotation or in 2 different reciprocating motions. Methods: A total of 180 nickel-titanium files from 4 brands marketed, 2 for use in reciprocating motion.(ie, Reciproc R25 and Wave One Primary) and 2 for use in continuous rotation (ie, Mtwo and TF both taper .06/0.25 tip diameter), were tested. Forty-five instruments for each brand were divided into 3 groups (n = 15) on the basis of the motion tested: continuous rotation (group 1: 300 rpm) and reciprocal motion (group 2: "RECIPROC ALL" mode and group 3: "WAVEONE ALL" mode). The resistance to cyclic fatigue was determined by counting the number of cycles to failure in a 60 degrees curve with a 5-mm radius. Data were analyzed through 2-way analyses of variance. Results: The cyclic fatigue resistance of the 2 reciprocating motion instruments (ie, "RECIPROC ALL" and "WAVEONE ALL") was significantly higher than the continuous rotation in each brand (P < .001). No significant difference was observed in cyclic fatigue between the 2 different reciprocal motions tested in each brand (P > .05). When considering the appropriate clinical motion for each brand, no significant difference in cyclic fatigue was found between TF, Mtwo, and Reciproc R25 instruments, whereas the cyclic fatigue resistance of WaveOne files was less than the other 3 brands (P < .05). Conclusions: Reciprocal motion showed a significantly higher cyclic fatigue resistance in all brands compared with continuous rotation. No differences were found between the 2 reciprocating motions. (J Endod 2013;39:258-261)
引用
收藏
页码:258 / 261
页数:4
相关论文
共 26 条
  • [1] An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel-Titanium Rotary Instruments
    Bhagabati, Nilav
    Yadav, Seema
    Talwar, Sangeeta
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (04) : 515 - 518
  • [2] Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement
    De-Deus, G.
    Moreira, E. J. L.
    Lopes, H. P.
    Elias, C. N.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (12) : 1063 - 1068
  • [3] Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique
    Gambarini, G.
    Plotino, G.
    Grande, N. M.
    Al-Sudani, D.
    De Luca, M.
    Testarelli, L.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) : 337 - 341
  • [4] Effects of Raw Material and Rotational Speed on the Cyclic Fatigue of ProFile Vortex Rotary Instruments
    Gao, Yong
    Shotton, Vincent
    Wilkinson, Kevin
    Phillips, Greg
    Ben Johnson, William
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1205 - 1209
  • [5] Resistance to Flexural Fatigue of Reciproc R25 Files under Continuous Rotation and Reciprocating Movement
    Gavini, Giulio
    Caldeira, Celso Luiz
    Akisue, Eduardo
    de Miranda Candeiro, George Taccio
    Sacaguti Kawakami, Dirce Akemi
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (05) : 684 - 687
  • [6] Kim H, 2012, SPACE, P38
  • [7] Cyclic Fatigue and Fracture Characteristics of Ground and Twisted Nickel-Titanium Rotary Files
    Kim, Hyeon-Cheol
    Yum, Jiwan
    Hur, Bock
    Cheung, Gary Shun-Pan
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (01) : 147 - 152
  • [8] Cyclic fatigue of endodontic nickel titanium rotary instruments: Static and dynamic tests
    Li, UM
    Lee, BS
    Shih, CT
    Lan, WH
    Lin, CP
    [J]. JOURNAL OF ENDODONTICS, 2002, 28 (06) : 448 - 451
  • [9] Rotary NiTi instrument fracture and its consequences
    Parashos, Peter
    Messer, Harold H.
    [J]. JOURNAL OF ENDODONTICS, 2006, 32 (11) : 1031 - 1043
  • [10] Dynamic Torsional Resistance of Nickel-Titanium Rotary Instruments
    Park, Su-Young
    Cheung, Gary S. P.
    Yum, Jiwan
    Hur, Bock
    Park, Jeong-Kil
    Kim, Hyeon-Cheol
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1200 - 1204