The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup - Spatial orientation of the pelvis in different positions

被引:46
作者
Mayr, E [1 ]
Kessler, O
Prassl, A
Rachbauer, F
Krismer, M
Nogler, M
机构
[1] Innsbruck Med Univ, Dept Orthopaed Surg, Innsbruck, Austria
[2] Stryker Europe, Thalwil, Thailand
关键词
D O I
10.1080/17453670510045471
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The frontal pelvic plane has traditionally served as the reference plane for implantation of the acetabular cup during total hip arthroplasty, with referencing performed with the patient supine on the operating table. During daily activities in an upright position, the frontal pelvic plane changes from a horizontal to a vertical orientation. If this change in orientation is accompanied by a substantial change in pelvic inclination angle, it would mean that the use of the frontal pelvic plane as a reference plane for implantation of the acetabular cup would not be valid for proper alignment of the cup. To evaluate this possibility, we measured the change of inclination of the pelvis from the supine to the standing position. Subjects and methods We evaluated 120 patients, first positioned in a standing position and then supine on a table. Three pelvic landmarks were digitized percutaneously, and the spatial coordinates were calculated with regard to pelvic orientation in the horizontal and the vertical plane. Results We found a mean inclination of 6.7 degrees in the standing position and 5.6 degrees in the supine position. Patients who were more than 60 years of age who did not have coxarthrosis had a greater inclination angle (8.7 degrees) while standing. Pelvic orientation was stable with regard to the supine and standing positions. These results were independent of sex, level of arthrosis, or status after implantation of a total hip replacement. Interpretation The frontal pelvic plane is a valid reference plane for implantation of the acetabular cup.
引用
收藏
页码:848 / 853
页数:6
相关论文
共 10 条
  • [1] ANDA S, 1990, ACTA RADIOL, V31, P389
  • [2] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [3] Eddine TA, 2001, SURG RADIOL ANAT, V23, P105
  • [4] GELB DE, 1995, SPINE, V20, P1351, DOI 10.1097/00007632-199506000-00005
  • [5] Accuracy of intraoperative assessment of acetabular prosthesis placement
    Hassan, DM
    Johnston, GHF
    Dust, WNC
    Watson, G
    Dolovich, AT
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 80 - 84
  • [6] Computer assisted measurement of cup placement in total hip replacement
    Jaramaz, B
    DiGioia, AM
    Blackwell, M
    Nikou, C
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) : 70 - 81
  • [7] Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
  • [8] McKibbin B, 1970, J Bone Joint Surg Br, V52, P148
  • [9] NISHIHARA S, 2003, CLIN ORTHOP RELAT R, V411, P140
  • [10] Williams P.L., 1989, GRAYS ANATOMY