Free-running 4D whole-heart self-navigated golden angle MRI: Initial results

被引:88
作者
Coppo, Simone [1 ,2 ,3 ]
Piccini, Davide [1 ,2 ,3 ,4 ]
Bonanno, Gabriele [1 ,2 ,3 ]
Chaptinel, Jerome [1 ,2 ,3 ]
Vincenti, Gabriella [3 ,5 ]
Feliciano, Helene [1 ,2 ,3 ]
van Heeswijk, Ruud B. [1 ,2 ,3 ]
Schwitter, Juerg [3 ,5 ]
Stuber, Matthias [1 ,2 ,3 ]
机构
[1] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[2] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[3] Univ Lausanne UNIL, Lausanne, Switzerland
[4] Siemens Healthcare IM BM PI, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Univ Hosp CHUV, Dept Cardiol, Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
cardiac; coronary; function; four dimensional; whole heart; self-navigation; golden angle; radial; MAGNETIC-RESONANCE ANGIOGRAPHY; RADIAL SSFP ACQUISITION; STATE FREE PRECESSION; CORONARY MRA; SINGLE-CENTER; RECONSTRUCTION; VISUALIZATION; EXPERIENCE; STRATEGIES; MOTION;
D O I
10.1002/mrm.25523
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. MethodsA free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. ResultsThe 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3). Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. ConclusionThe hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med 74:1306-1316, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1306 / 1316
页数:11
相关论文
共 40 条
[1]   Accelerated Isotropic Sub-Millimeter Whole-Heart Coronary MRI: Compressed Sensing Versus Parallel Imaging [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Chan, Raymond H. ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) :815-822
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   Comparison of fat suppression strategies in 3D spiral coronary magnetic resonance angiography [J].
Börnert, P ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Manning, WJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :462-466
[4]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[5]  
Coppo S, 2014, J CARDIOVASC MAGN S1, V16, pO18
[6]  
Coppo S, 2014, P 22 JOINT ANN M ISM
[7]   Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function [J].
Eberle, Holger C. ;
Nassenstein, Kai ;
Jensen, Christoph J. ;
Schlosser, Thomas ;
Sabin, Georg V. ;
Naber, Christoph K. ;
Bruder, Oliver .
EUROPEAN RADIOLOGY, 2010, 20 (01) :73-80
[8]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[9]   Coronary MR angiography at 3T during diastole and systole [J].
Gharib, Ahmed M. ;
Herzka, Daniel A. ;
Ustun, Ali O. ;
Desai, Milind Y. ;
Locklin, Julia ;
Pettigrew, Roderic I. ;
Stuber, Matthias .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) :921-926
[10]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210