Performance study of solar air heater having v-down discrete ribs on absorber plate

被引:95
|
作者
Karwa, Rajendra [1 ]
Chitoshiya, Girish [2 ]
机构
[1] JIET Sch Engn & Technol Girls, Jodhpur 342002, Rajasthan, India
[2] Jai Narain Vyas Univ, Fac Engn & Architecture, Dept Mech Engn, Jodhpur 342011, Rajasthan, India
关键词
Smooth and roughened duct solar air heater (collector); V-down discrete rib roughness; Thermal efficiency; Effective efficiency; FRICTION FACTOR CORRELATIONS; THERMOHYDRAULIC PERFORMANCE; TRANSFER COEFFICIENT; THERMAL PERFORMANCE; FLUID-FLOW; ROUGHNESS; TRANSVERSE; DUCTS; COLLECTOR; ANGLE;
D O I
10.1016/j.energy.2013.03.068
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper presents results of an experimental study of thermo-hydraulic performance of a solar air heater with 60 degrees v-down discrete rib roughness on the airflow side of the absorber plate along with that for a smooth duct air heater. The enhancement in the thermal efficiency due to the roughness on the absorber plate is found to be 12.5-20% depending on the airflow rate; higher enhancement is at the lower flow rate. The experimental data have been generated and utilized to validate a mathematical model, which can be utilized for design and prediction of performance of both smooth and roughened air heaters under different operating conditions. The results of a detailed thermo-hydraulic performance study of solar air heater with v-down discrete rib roughness using the mathematical model are also presented along with the effect of variation of various parameters on the performance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:939 / 955
页数:17
相关论文
共 50 条
  • [21] Thermal and thermohydraulic performance of roughened solar air heater having protruded absorber plate
    Bhushan, Brij
    Singh, Ranjit
    SOLAR ENERGY, 2012, 86 (11) : 3388 - 3396
  • [22] Performance of Solar Air Heater Having Absorber Plate Roughened with Protrusions of Different Shapes
    Soi, Aman
    Singh, Ranjit
    Bhushan, Brij
    PROCEEDINGS OF 2019 IEEE 2ND INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND POWER ENGINEERING (REPE 2019), 2019, : 177 - 181
  • [23] Experimental testing of solar-based air heater roughed with discrete V-down rib and staggered element
    Jain, Piyush Kumar
    Lanjewar, Atul
    Chaurasiya, Prem Kumar
    Tiwari, Damodar
    Sharma, Vinod Kumar
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (15) : 43137 - 43151
  • [24] Performance Evaluation of Solar Air Heater Having Chamfered Rib Groove Roughness on Absorber Plate
    Layek, Apurba
    INTERNATIONAL CONFERENCE ON MODELING, OPTIMIZATION, AND COMPUTING, 2010, 1298 : 282 - 287
  • [25] Nusselt number and friction factor correlations for solar air heater duct with broken V-down ribs combined with staggered rib roughness
    Patil, Anil K.
    Saini, J. S.
    Kumar, K.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (03)
  • [26] Prediction of thermal efficiency of double pass solar air heater having discrete multi V and staggered ribs
    Ravi, Ravi Kant
    Kumar, Sanjay
    Kumar, Mukesh
    Kumar, Manoj
    Verma, Vikas
    Alam, Tabish
    Yadav, Anil Singh
    Sharma, Abhishek
    HEAT TRANSFER, 2025, 54 (01) : 41 - 65
  • [27] Performance analysis on Solar Air Heater with Discrete Arc Shaped Rib Element in Absorber Plate
    Makeshkumar, M.
    Thangavel, P.
    INTERNATIONAL CONFERENCE ON MECHATRONICS IN ENERGY AND ENVIRONMENT PROTECTION (ICMEEP 2020), 2020, 995
  • [28] Improving the performance of solar air heater using a new model of V-corrugated absorber plate having perforations jets
    Abd, Hareth Maher
    Alomar, Omar Rafae
    Salih, Mothana M. Mohamed
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (06) : 8130 - 8144
  • [29] Performance evaluation of solar air heater having expanded metal mesh as artificial roughness on absorber plate
    Gupta, M. K.
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (05) : 1007 - 1016
  • [30] Thermo-hydraulic performance of solar air heater having twisted rib over the absorber plate
    Kumar, Anup
    Layek, Apurba
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 133 : 181 - 195