Modelling Mixed-Gas Sorption in Glassy Polymers for CO2 Removal: A Sensitivity Analysis of the Dual Mode Sorption Model

被引:48
作者
Ricci, Eleonora [1 ]
De Angelis, Maria Grazia [1 ]
机构
[1] Univ Bologna, Dept Civil Chem Environm & Mat Engn, I-40131 Bologna, Italy
关键词
dual mode sorption model; mixed-gas sorption; PIMs; glassy polymers; INTRINSIC MICROPOROSITY PIM-1; CO2/CH4; MIXTURES; VAPOR SORPTION; 3,3'-DIHYDROXY-4,4'-DIAMINO-BIPHENYL HAB; DESIGN CONSIDERATIONS; PRESSURE-DEPENDENCE; PREDICTIVE MODEL; ETHYL CELLULOSE; SMALL MOLECULES; MONTE-CARLO;
D O I
10.3390/membranes9010008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In an effort to reduce the experimental tests required to characterize the mixed-gas solubility and solubility-selectivity of materials for membrane separation processes, there is a need for reliable models which involve a minimum number of adjustable parameters. In this work, the ability of the Dual Mode Sorption (DMS) model to represent the sorption of CO2/CH4 mixtures in three high free volume glassy polymers, poly(trimethylsilyl propyne) (PTMSP), the first reported polymer of intrinsic microporosity (PIM-1) and tetrazole-modified PIM-1 (TZ-PIM), was tested. The sorption of gas mixtures in these materials suitable for CO2 separation has been characterized experimentally in previous works, which showed that these systems exhibit rather marked deviations from the ideal pure-gas behavior, especially due to competitive effects. The accuracy of the DMS model in representing the non-idealities that arise during mixed-gas sorption was assessed in a wide range of temperatures, pressures and compositions, by comparing with the experimental results available. Using the parameters obtained from the best fit of pure-gas sorption isotherms, the agreement between the mixed-gas calculations and the experimental data varied greatly in the different cases inspected, especially in the case of CH4 absorbed in mixed-gas conditions. A sensitivity analysis revealed that pure-gas data can be represented with the same accuracy by several different parameter sets, which, however, yield markedly different mixed-gas predictions, that, in some cases, agree with the experimental data only qualitatively. However, the multicomponent calculations with the DMS model yield more reliable results than the use of pure-gas data in the estimation of the solubility-selectivity of the material.
引用
收藏
页数:26
相关论文
共 102 条
[1]  
Abadie J, 1969, Optimization, P37
[2]  
Allen M, 1987, DJ Tildesley Computer simulation of liquids
[3]  
[Anonymous], ENCY MEMBRANE SCI TE
[4]   Natural gas processing with membranes: An overview [J].
Baker, Richard W. ;
Lokhandwala, Kaaeid .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (07) :2109-2121
[5]   Gas Separation Membrane Materials: A Perspective [J].
Baker, Richard W. ;
Low, Bee Ting .
MACROMOLECULES, 2014, 47 (20) :6999-7013
[6]   SORPTION AND DIFFUSION IN ETHYL CELLULOSE .3. COMPARISON BETWEEN ETHYL CELLULOSE AND RUBBER [J].
BARRER, RM ;
BARRIE, JA ;
SLATER, J .
JOURNAL OF POLYMER SCIENCE, 1958, 27 (115) :177-197
[7]  
Bevington P., 2003, Data Reduction and Error Analysis for the Physical Sciences, Vthird
[8]  
Bondar VI, 1996, J POLYM SCI POL PHYS, V34, P369, DOI 10.1002/(SICI)1099-0488(19960130)34:2<369::AID-POLB18>3.0.CO
[9]  
2-H
[10]  
Boulougouris GC, 1999, MOL PHYS, V96, P905, DOI 10.1080/00268979909483030