Effect of channel geometry on cell adhesion in microfluidic devices

被引:58
作者
Green, James V. [1 ]
Kniazeva, Tatiana [1 ]
Abedi, Mehdi [2 ]
Sokhey, Darshan S. [1 ]
Taslim, Mohammad E. [2 ]
Murthy, Shashi K. [1 ]
机构
[1] Northeastern Univ, Dept Chem Engn, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Mech & Ind Engn, Boston, MA 02115 USA
关键词
ENDOTHELIAL-CELLS; SMOOTH-MUSCLE; FLOW; SEPARATION; BLOOD;
D O I
10.1039/b813516a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic channels coated with ligands are a versatile platform for the separation or enrichment of cells from small sample volumes. This adhesion-based mode of separation is mediated by ligand receptor bonds between the cells and channel surface and also by fluid shear stress. This paper demonstrates how aspects of microchannel geometry can play an additional role in controlling cell adhesion. With a combination of computational fluid dynamics modeling and cell adhesion experiments, channels with sharp turns are shown to have regions with near-zero velocity at the turn regions where large numbers of cells adhere or become collected. The lack of uniform adhesion in the turn regions compared to other regions of these channels, together with the large variability in observed cell adhesion indicates that channels with sharp turns are not optimal for cell-capture applications where predictable cell adhesion is desired. Channels with curved turns, on the other hand are shown to provide more uniform and predictable cell adhesion provided the gap between parallel arms of the channels is sufficiently wide. The magnitude of cell adhesion in these curved channels is comparable to that in straight channels with no turns.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 18 条
[1]   A microfluidic device for practical label-free CD4+T cell counting of HIV-infected subjects [J].
Cheng, Xuanhong ;
Irimia, Daniel ;
Dixon, Meredith ;
Sekine, Kazuhiko ;
Demirci, Utkan ;
Zamir, Lee ;
Tompkins, Ronald G. ;
Rodriguez, William ;
Toner, Mehmet .
LAB ON A CHIP, 2007, 7 (02) :170-178
[2]   Recognition and capture of breast cancer cells using an antibody-based platform in a microelectromechanical systems device [J].
Du, Z. ;
Cheng, K. H. ;
Vaughn, M. W. ;
Collie, N. L. ;
Gollahon, L. S. .
BIOMEDICAL MICRODEVICES, 2007, 9 (01) :35-42
[3]   Microfluidic-based diagnostics for cervical cancer cells [J].
Du, Z ;
Colls, N ;
Cheng, KH ;
Vaughn, MW ;
Gollahon, L .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (10) :1991-1995
[4]   Flow-induced deformation of shallow microfluidic channels [J].
Gervais, T ;
El-Ali, J ;
Günther, A ;
Jensen, KF .
LAB ON A CHIP, 2006, 6 (04) :500-507
[5]  
HARBECK N, 1995, INT J ONCOL, V6, P1249
[6]   HIGH-GRADIENT MAGNETIC CELL-SEPARATION WITH MACS [J].
MILTENYI, S ;
MULLER, W ;
WEICHEL, W ;
RADBRUCH, A .
CYTOMETRY, 1990, 11 (02) :231-238
[7]   Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers [J].
Murthy, SK ;
Sin, A ;
Tompkins, RG ;
Toner, M .
LANGMUIR, 2004, 20 (26) :11649-11655
[8]   Isolation of rare circulating tumour cells in cancer patients by microchip technology [J].
Nagrath, Sunitha ;
Sequist, Lecia V. ;
Maheswaran, Shyamala ;
Bell, Daphne W. ;
Irimia, Daniel ;
Ulkus, Lindsey ;
Smith, Matthew R. ;
Kwak, Eunice L. ;
Digumarthy, Subba ;
Muzikansky, Alona ;
Ryan, Paula ;
Balis, Ulysses J. ;
Tompkins, Ronald G. ;
Haber, Daniel A. ;
Toner, Mehmet .
NATURE, 2007, 450 (7173) :1235-U10
[9]   Microfluidic depletion of endothelial cells, smooth muscle cells, and fibroblasts from heterogeneous suspensions [J].
Plouffe, Brian D. ;
Radisic, Milica ;
Murthy, Shashi K. .
LAB ON A CHIP, 2008, 8 (03) :462-472
[10]   Peptide-mediated selective adhesion of smooth muscle and endothelial cells in microfluidic shear flow [J].
Plouffe, Brian D. ;
Njoka, Danson N. ;
Harris, Joscelyn ;
Liao, Jiahui ;
Horick, Nora K. ;
Radisic, Milica ;
Murthy, Shashi K. .
LANGMUIR, 2007, 23 (09) :5050-5055