Paper-based ELISA for fast CA 15-3 detection in point-of-care

被引:12
作者
Carneiro, Mariana C. C. G. [1 ,2 ,4 ]
Rodrigues, Ligia R. [2 ,4 ]
Moreira, Felismina T. C. [1 ,2 ,4 ]
Sales, M. Goreti F. [2 ,3 ,4 ]
机构
[1] Polytech Inst, Sch Engn, BioMark ISEP, Porto, Portugal
[2] Minho Univ, Ctr Biol Engn, CEB, Braga, Portugal
[3] Coimbra Univ, Fac Sci & Technol, Dept Chem Engn, BioMark UC, Coimbra, Portugal
[4] LABBELS, Associate Lab, Braga, Portugal
关键词
paper-based ELISA; CA15-3; Colorimetric detection; Cancer detection; Breast cancer; BOVINE SERUM-ALBUMIN; CANCER; ASSAY; BIOMARKER; DEVICES; IMMUNODEVICE; IMMUNOASSAY;
D O I
10.1016/j.microc.2022.107756
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper-based Enzyme-Linked Immunosorbent Assay (P-ELISA) is a promising tool for diagnostic applications because the paper matrix is characterised by low cost, short analysis time, portability, and a high surface-to-volume ratio that allows the use of a small sample and reagent volume of a few microliters. In addition, colorimetric assays are suitable for low-resource areas due to their simplicity and naked-eye detectability. Although several works have been reported using paper-based colorimetric sensors for cancer biomarkers, P-ELISA for cancer antigen 15-3 (CA 15-3) has never been reported. Thus, this work reports the development of a rapid, simple and relatively inexpensive paper-based colorimetric assay for the detection of CA 15-3 as cancer biomarker. The assay was developed on a filter paper that was previously washed and chemically oxidized with periodate to generate aldehyde functional groups on the cellulose surface. After covalent binding of the first antibody, detection was performed by a colorimetric reaction based on the oxidation of the substrate 3,3',5,5' -tetramethylbenzidine (TMB) by a peroxidase enzyme in the presence of H2O2. The colorimetric measurement was based on digital image acquisition analysed using ImageJ software. The linear range of the assay in buffer ranged 2 to 1100 U/mL. The performance of the assay was also successfully tested in human serum from Cormay (R), offering a linear range from 2 to 200 U/mL. Thus, this P-ELISA sensor is suitable for the analysis of serum samples, since the physiological value in cancer patients is 30 U/mL. We believe that this proof-of-concept has the potential to be extended to be applied to other protein biomarkers and to be a suitable tool for cancer screening in developing countries.
引用
收藏
页数:9
相关论文
共 55 条
[1]   A colorimetric paper sensor for citrate as biomarker for early stage detection of prostate cancer based on peroxidase-like activity of cysteine-capped gold nanoclusters [J].
Abarghoei, Shima ;
Fakhri, Neda ;
Borghei, Yasaman Sadat ;
Hosseini, Morteza ;
Ganjali, Mohammad Reza .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 210 :251-259
[2]  
Agarwal C., 2019, Sustainable Polymer Composites and Nanocomposites, P479
[3]   Mimicking peroxidase activity of Co2(OH)2CO3-CeO2 nanocomposite for smartphone based detection of tumor marker using paper-based microfluidic immunodevice [J].
Alizadeh, Negar ;
Salimi, Abdollah ;
Hallaj, Rahman .
TALANTA, 2018, 189 :100-110
[4]   Study on Enzyme Linked Immunosorbent Assay Using Paper-based Micro-zone Plates [J].
Bai Peng ;
Luo Yan ;
Li Ying ;
Yu Xiao-Dong ;
Chen Hong-Yuan .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (01) :20-24
[5]   Molecular Markers for Breast Cancer: Prediction on Tumor Behavior [J].
Banin Hirata, Bruna Karina ;
Maeda Oda, Julie Massayo ;
Guembarovski, Roberta Losi ;
Ariza, Carolina Batista ;
Coral de Oliveira, Carlos Eduardo ;
Ehara Watanabe, Maria Angelica .
DISEASE MARKERS, 2014, 2014
[6]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[7]   Simple and sensitive colorimetric assay system for horseradish peroxidase using microfluidic paper-based devices [J].
Busa, Lori Shayne Alamo ;
Maeki, Masatoshi ;
Ishida, Akihiko ;
Tani, Hirofumi ;
Tokeshi, Manabu .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 :433-441
[8]  
Cerda-Kipper AS., 2019, Encyclopedia of Analytical Science, P55, DOI [DOI 10.1016/B978-0-12-409547-2.14510-X, 10.1016/b978-0-12-409547-2.14510-x]
[9]   Distance-based carcinoembryonic antigen assay on microfluidic paper immunodevice [J].
Chen, Ying ;
Chu, Weiru ;
Liu, Wei ;
Guo, Xiaoyan .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 :452-459
[10]   Patterned Photonic Nitrocellulose for Pseudopaper ELISA [J].
Chi, Junjie ;
Gao, Bingbing ;
Sun, Mi ;
Zhang, Fengling ;
Su, Enben ;
Liu, Hong ;
Gu, Zhongze .
ANALYTICAL CHEMISTRY, 2017, 89 (14) :7727-7733