摘要
Peptides and proteins were separated by capillary electrophoresis (CE) in fused-silica capillaries coated with an irreversibly adsorbed monolayer of derivatized polystyrene nanoparticles. Whereas phosphate buffer, pH 3.10, enabled the highly efficient separation of basic proteins with plate counts up to 1 400 000 m(-1), volatile buffer components such as formic acid or acetic acid titrated with ammonia to the desired pH had to be used for the direct coupling of CE with electrospray ionization mass spectrometry (ESI-MS). Compared to 40 mM phosphoric acid-sodium hydroxide, pH 3.10, a background electrolyte containing 125 mM formic acid-ammonia, pH 4.00, was shown to yield equivalent separation efficiency. Investigation of the influence of buffered electrolytes on the ESI-MS signal of lysozyme at pH 2.70-4.00 showed that the charge state distribution shifted to lower charge states at higher pH with a concomitant five-fold decrease in signal intensity of the most abundant signal. The presence of trifluoroacetic acid in the background electrolyte greatly increased the level of baseline noise and completely inhibited the observation of any mass signals related to proteins. Full scan spectra could be acquired from 50-500 fmol amounts of proteins during coupled CE-ESI-NIS utilizing 100-125 mM formic acid-ammonia, pH 3.10. However, compared to UV detection, considerable band broadening is observed with ESI-MS detection which is mainly attributed to column overloading, band spreading in the interface, and scanning data acquisition. Finally, the major whey proteins beta-lactoglobulin A, beta-lactoglobulin B, and alpha-lactalbumin were identified in a whey drink by comparison of molecular masses determined by CE-ESI-MS to molecular masses calculated from the amino acid sequence. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [41] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [42] Coupling of capillary electrophoresis with electrospray ionization multiplexing ion mobility spectrometry
    Guo, Jianheng
    Li, Guozhu
    Zhang, Hanghang
    Jia, Xu
    Meng, Qingyan
    Liu, Wenjie
    ELECTROPHORESIS, 2019, 40 (12-13) : 1639 - 1647
  • [43] Capillary electrophoresis-electrospray ionization-mass spectrometry method to determine the phenolic fraction of extra-virgin olive oil
    Carrasco-Pancorbo, Alegria
    Arraez-Roman, David
    Segura-Carretero, Antonio
    Fernandez-Gutierrez, Alberto
    ELECTROPHORESIS, 2006, 27 (11) : 2182 - 2196
  • [44] Capillary zone electrophoresis electrospray mass spectrometry of priority phenols
    Tsai, CY
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (02) : 315 - 321
  • [45] Effects of experimental parameters on the signal intensity of capillary electrophoresis electrospray ionization mass spectrometry in protein analysis
    Liang, Z
    Yang, Q
    Zhang, WB
    Zhang, LH
    Zhang, YK
    CHROMATOGRAPHIA, 2003, 57 (9-10) : 617 - 621
  • [46] Capillary electrophoresis-electrospray-mass spectrometry in peptide analysis and peptidomics
    Herrero, Miguel
    Ibanez, Elena
    Cifuentes, Alejandro
    ELECTROPHORESIS, 2008, 29 (10) : 2148 - 2160
  • [47] Effects of experimental parameters on the signal intensity of capillary electrophoresis electrospray ionization mass spectrometry in protein analysis
    Zhen Liang
    Qing Yang
    Weibing Zhang
    Lihua Zhang
    Yukui Zhang
    Chromatographia, 2003, 57 : 617 - 621
  • [48] The development of a sheathless capillary electrophoresis electrospray ionization-mass spectrometry interface based on thin conducting liquid film
    Huang, Ju-Li
    Hsu, Ren-Yu
    Her, Guor-Rong
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 131 - 137
  • [49] Isolation and characterization of β-cyclodextrin sulfates by preparative gradient polyacrylamide gel electrophoresis, capillary electrophoresis and electrospray ionization-mass spectrometry
    Hileman, RE
    Siegel, MM
    Tabei, K
    Balagurunathan, K
    Linhardt, RJ
    ELECTROPHORESIS, 1998, 19 (15) : 2677 - 2681
  • [50] Operational variables in high-performance liquid chromatography-electrospray ionization mass spectrometry of peptides and proteins using poly(styrene-divinylbenzene) monoliths
    Walcher, W
    Toll, H
    Ingendoh, A
    Huber, CG
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1053 (1-2) : 107 - 117