Investigation on humidification effect of desiccant coated heat exchanger for improving indoor humidity environment in winter

被引:14
|
作者
Sun, X. Y. [1 ,2 ]
Dai, Y. J. [1 ,2 ]
Ge, T. S. [1 ,2 ]
Zhao, Y. [1 ,2 ]
Wang, R. Z. [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] MOE, Engn Res Ctr Solar Power & Refrigerat, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Desiccant-coated heat exchanger; Desiccant materials; Variable structure sizes; Humidification capacity; AIR-CONDITIONING SYSTEM; LIQUID DESICCANT; MASS-TRANSFER; DEHUMIDIFICATION; UNIT;
D O I
10.1016/j.enbuild.2018.01.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In cold climates, keeping proper temperature and humidity level is essential to ensure a comfortable and healthy building environment. In this paper, a new method is developed to meet the demand for humidifying the indoor air in winter by using desiccant coated heat exchanger (DCHE) as a heating and humidifying unit during the regeneration process. The desiccant coating materials and configurations of DCHE are two main aspects affecting the humidification performance. With the same heat and mass transfer area but different structure sizes, PCHE (fin pitch 2 mm, fin depth 44 mm), SCHE A (fin pitch 2 mm, fin depth 44 mm), SCHE B (fin pitch 3 mm, fin depth 66 mm) and SCHE C (fin pitch 4 mm, fin depth 88 mm) are fabricated and tested. The heat and moisture transfer characteristics of four types of DCHE under various operation conditions are compared with test results. In one typical cycle, the average moisture added in winter of PCHE, SCHE A, SCHE B and SCHE C is 1.73 g/kg(DA), 1.53 g/kg(DA), 1.49 g/kg(DA) and 1.41 g/kg(DA), respectively. Compared with silica gel, potassium format compound desiccant helps improving humidification performance by 13%. Also performed is the dynamic analysis on moisture transfer mechanisms and mass transfer coefficient in a typical cycle, the results indicate that the potassium format compound desiccant coated heat exchanger performs the best. PCHE shows the highest humidification capacity, SCHE A shows the highest heating capacity, while SCHE C shows the highest heat recovery efficiency. With heating fluid temperature increasing from 40 degrees C to 60 degrees C, the humidification amount of four DCHE5 increase by 30%. The optimal inlet air velocity is given as 1.60 m/s, considering humidification amount and heat recovery efficiency synthetically. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] Experimental investigation on solar powered desiccant coated heat exchanger humidification air conditioning system in winter
    Zhang, J. Y.
    Ge, T. S.
    Dai, Y. J.
    Zhao, Y.
    Wang, R. Z.
    ENERGY, 2017, 137 : 468 - 478
  • [2] Experimental investigation on performance of a novel composite desiccant coated heat exchanger in summer and winter seasons
    Valarezo, Andres S.
    Sun, X. Y.
    Ge, T. S.
    Dai, Y. J.
    Wang, R. Z.
    ENERGY, 2019, 166 : 506 - 518
  • [3] Experimental investigation on performance of desiccant coated heat exchanger and sensible heat exchanger operating in series
    Ge, T. S.
    Cao, W.
    Pan, X.
    Dai, Y. J.
    Wang, R. Z.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 83 : 88 - 98
  • [4] Desiccant coated heat exchanger and its applications
    Zhao, L. H.
    Wang, R. Z.
    Ge, T. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 217 - 232
  • [5] Investigation on energy consumption of desiccant coated heat exchanger based heat pump: Limitation of adsorption heat of desiccant
    Zheng, X.
    Wang, R. Z.
    Tu, Y. D.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 188 : 473 - 479
  • [6] Performance study of desiccant coated heat exchanger air conditioning system in winter
    Ge, T. S.
    Dai, Y. J.
    Wang, R. Z.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 123 : 559 - 568
  • [7] Experimental investigation on a compact fresh air humidification/ dehumidification system based on desiccant coated heat pump
    Yang, Tianyu
    Ge, Tianshu
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 59 - 67
  • [8] Performance evaluation of a desiccant coated heat exchanger with two different desiccant materials
    Erkek, Turkan Ucok
    Gungor, Ali
    Fugmann, Hannes
    Morgenstern, Alexander
    Bongs, Constanze
    APPLIED THERMAL ENGINEERING, 2018, 143 : 701 - 710
  • [9] Gravimetric method for sorption performance measurement of desiccant wheel and desiccant coated heat exchanger
    Higashi, Tomohiro
    Yamaguchi, Mao
    Nakagawa, Naoki
    Dang, Chaobin
    Hihara, Eiji
    APPLIED THERMAL ENGINEERING, 2018, 144 : 639 - 646
  • [10] Experimental investigation on a dehumidification unit with heat recovery using desiccant coated heat exchanger in waste to energy system
    Sun, X. Y.
    Chen, J. L.
    Zhao, Y.
    Li, X.
    Ge, T. S.
    Wang, C. H.
    Dai, Y. J.
    APPLIED THERMAL ENGINEERING, 2021, 185