摘要
Objectives: To investigate the agreement between optical coherence tomography (OCT) and OCT-based angiography in estimating retinal nerve fiber layer thickness (RNFLT) and evaluate the associations between peripapillary vessel density (VD) and RNFLT measurements obtained with both devices. Materials and Methods: The AngioVue (Optovue Inc., Fremont, CA, USA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) images of 325 patients were screened retrospectively. RNFLT values were recorded using both devices. The intraclass correlation coefficient (ICC) and Bland-Altman plots were obtained to investigate the agreement between the devices. Age- and intraocular pressurecorrected associations between VD and RNFLT measured by the two devices were analyzed using linear regression models. Results: ICC revealed excellent agreement for global, superior, inferior, and temporal RNFLT and good agreement for the nasal quadrant (ICC=0.895, 0.936, 0.923, 0.887, and 0.614, respectively). The Bland-Altman plots showed poor agreement for all measurements with a large span of limits of agreement and significant proportional bias (p<0.05). VD was found to be strongly associated with the RNFLT measurements of both devices (p<0.001). Conclusion: The disagreement between the devices should be considered in clinical practice, and the data should not be used interchangeably. The association of the peripapillary VD with RNFLT using both devices indicated that RNFLT assessed by the AngioVue could be used in glaucoma management along with VD.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 33 条
[11]   Influence of Removing the Large Retinal Vessels-related Effect on Peripapillary Vessel Density Progression Analysis in Glaucoma [J].
Hollo, Gabor .
JOURNAL OF GLAUCOMA, 2018, 27 (08) :E137-E139
[12]   Comparison of Peripapillary OCT Angiography Vessel Density and Retinal Nerve Fiber Layer Thickness Measurements for Their Ability to Detect Progression in Glaucoma [J].
Hollo, Gabor .
JOURNAL OF GLAUCOMA, 2018, 27 (03) :302-305
[13]   Comparison of repeatability of swept-source and spectral-domain optical coherence tomography for measuring inner retinal thickness in retinal disease [J].
Hong, Eun Hee ;
Ryu, So Jung ;
Kang, Min Ho ;
Seong, Mincheol ;
Cho, Heeyoon ;
Yeom, Jong Hun ;
Shin, Yong Un .
PLOS ONE, 2019, 14 (01)
[14]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[15]   Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography [J].
Kanamori, A ;
Nakamura, M ;
Escano, MFT ;
Seya, R ;
Maeda, H ;
Negi, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) :513-520
[16]   Ability of stratus OCT to identify localized retinal nerve fiber layer defects in patients with normal standard automated perimetry results [J].
Kim, Tae-Woo ;
Park, Un-Chul ;
Park, Ki Ho ;
Kim, Dong Myung .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (04) :1635-1641
[17]   Cirrus High-definition Optical Coherence Tomography Versus Spectral Optical Coherence Tomography/Scanning Laser Ophthalmoscopy in the Diagnosis of Glaucoma [J].
Koh, Kyung Min ;
Jin, Sunyoung ;
Hwang, Young Hoon .
CURRENT EYE RESEARCH, 2014, 39 (01) :62-68
[18]   Optical coherence tomography angiography: an overview of the technology and an assessment of applications for clinical research [J].
Koustenis, Andrew, Jr. ;
Harris, Alon ;
Gross, Josh ;
Januleviciene, Ingrida ;
Shah, Aaditya ;
Siesky, Brent .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (01) :16-20
[19]   Agreement Among Spectral-Domain Optical Coherence Tomography Instruments for Assessing Retinal Nerve Fiber Layer Thickness [J].
Leite, Mauro T. ;
Rao, Harsha L. ;
Weinreb, Robert N. ;
Zangwill, Linda M. ;
Bowd, Christopher ;
Sample, Pamela A. ;
Tafreshi, Ali ;
Medeiros, Felipe A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (01) :85-92
[20]   Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Qiu, Quanliang ;
Liu, Shu ;
Li, Haitao ;
Xu, Guihua ;
Fan, Ning ;
Huang, Lina ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2009, 116 (07) :1257-1263