Measurement of the Retention Time of Different Ophthalmic Formulations with Ultrahigh-Resolution Optical Coherence Tomography

被引:23
|
作者
Gagliano, Caterina [1 ,2 ,4 ]
Papa, Vincenzo [3 ]
Amato, Roberta [1 ]
Malaguarnera, Giulia [1 ,2 ]
Avitabile, Teresio [2 ]
机构
[1] Neurovisual Sci Technol NEST, Catania, Italy
[2] Univ Catania, Dept Ophthalmol, Catania, Italy
[3] Med Affairs SIFI SpA, Via Ercole Patti 36, I-95020 Catania, Italy
[4] Eye Clin S Marta Hosp, Catania, Italy
关键词
Xanthan gum; netilmicin; dexamethasone; OCT; tear film thickness; DRUG-DELIVERY; XANTHAN GUM; IN-VIVO; PRECORNEAL;
D O I
10.1080/02713683.2017.1418893
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose/aim of the study: The purpose of this study was to measure the pre-corneal retention time of two marketed formulations (eye drops and eye gel) of a steroid-antibiotic fixed combination (FC) containing 0.1% dexamethasone and 0.3% netilmicin.Materials and methods: Pre-corneal retention time was evaluated in 16 healthy subjects using an ultrahigh-resolution anterior segment spectral domain optical coherence tomography (OCT). All subjects randomly received both formulations of the FC (Netildex, SIFI, Italy). Central tear film thickness (CTFT) was measured before instillation (time 0) and then after 1, 10, 20, 30, 40 50, 60 and 120min. The pre-corneal retention time was calculated by plotting CTFT as a function of time. Differences between time points and groups were analyzed by Student's t-test.Results: CTFT increased significantly after the instillation of the eye gel formulation (p<0.001). CTFT reached its maximum value 1min after instillation and returned to baseline after 60min. No effect on CTFT was observed after the instillation of eye drops. The difference between the two formulations was statistically significant at time 1min (p<0.0001), 10min (p<0.001) and 20min (p<0.01).Conclusions: The FC formulated as eye gel was retained on the ocular surface longer than the corresponding eye drop solution. Consequently, the use of the eye gel might extend the interval between instillations and decrease the frequency of administration.
引用
收藏
页码:499 / 502
页数:4
相关论文
共 50 条
  • [1] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [2] Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler
    Uwe Morgner
    Ravi K. Ghanta
    Franz X. Kärtner
    Joel S. Schuman
    James G. Fujimoto
    Nature Medicine, 2001, 7 : 502 - 507
  • [4] Measurement of the retention time of different ophthalmic formulations with ultra-high resolution Optical Coherence Tomography
    Amato, Roberta
    Gagliano, Caterina
    Malaguarnera, Giulia
    Reibaldi, Michele
    Longo, Antonio
    Papa, Vincenzo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [6] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [7] Ultrahigh-resolution optical coherence tomography in glaucoma
    Wollstein, G
    Paunescu, LA
    Ko, TH
    Fujimoto, JG
    Kowalevicz, A
    Hartl, I
    Beaton, S
    Ishikawa, H
    Mattox, C
    Singh, O
    Duker, J
    Drexler, W
    Schuman, JS
    OPHTHALMOLOGY, 2005, 112 (02) : 229 - 237
  • [8] In vivo ultrahigh-resolution, functional optical coherence tomography
    Drexler, W.
    Morgner, U.
    Kaertner, F.
    Ghanta, R.K.
    Pitris, C.
    Li, X.
    Ippen, E.P.
    Fujimoto, J.G.
    Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest, 2000, : 416 - 418
  • [9] Optimal wavelength for ultrahigh-resolution optical coherence tomography
    Wang, YM
    Nelson, JS
    Chen, ZP
    Reiser, BJ
    Chuck, RS
    Windeler, RS
    OPTICS EXPRESS, 2003, 11 (12): : 1411 - 1417
  • [10] Measurement of Tear Film Thickness Using Ultrahigh-Resolution Optical Coherence Tomography
    Werkmeister, Rene M.
    Alex, Aneesh
    Kaya, Semira
    Unterhuber, Angelika
    Hofer, Bernd
    Riedl, Jasmin
    Bronhagl, Michael
    Vietauer, Martin
    Schmidl, Doreen
    Schmoll, Tilman
    Garhoefer, Gerhard
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    Groeschl, Martin
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5578 - 5583