Hot electron-induced cathodic electrochemiluminescence at oil film-covered carbon paste electrode and application to nano-molar determination of catechol

被引:15
作者
Chen, Xiao-Yan [1 ,2 ]
Zheng, Rui-Juan [1 ,3 ]
Qin, Su-Fang [1 ]
Sun, Jian-Jun [1 ]
机构
[1] Fuzhou Univ, Key Lab Anal & Detect Food Safety, Minist Educ,Coll Chem & Chem Engn, Fujian Prov Key Lab Anal Er Detect Technol Food S, Fuzhou 350108, Peoples R China
[2] Fujian Metrol Inst, Fuzhou 350003, Peoples R China
[3] Longyan Univ, Dept Chem & Mat Engn, Longyan 364000, Fujian, Peoples R China
基金
美国国家科学基金会; 国家科技攻关计划;
关键词
Carbon paste electrode; Cathodic electrochemiluminescence; Ru(bpy)(3)(2+)/S2O82- system; Catechol; TANTALUM ELECTRODES; ELECTROGENERATED CHEMILUMINESCENCE; ALUMINUM ELECTRODES; SILICON ELECTRODES; ELECTROLUMINESCENCE; INJECTION; GENERATION; HYDROQUINONE; LUMINESCENCE; FEASIBILITY;
D O I
10.1016/j.talanta.2012.09.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hot electron-induced cathodic electrochemiluminescence of the Ru(bpy)(3)(2+)/S2O82- system was investigated at an oil film-covered carbon paste electrode (CPE) under cathodic pulse polarization for the first time. Compared with other electrodes, the CPE is of lower background, better stability and reproducibility. The method is also applied to the determination of catechol. Under the optimum conditions, the linear correlation between the quenched ECL intensity (Delta I) and the logarithm of catechol concentration (log C-catechol) was observed over the range of 2.0 x 10(-10) mol/L-4.0 x 10(-9) mol/L and 4.0 x 10(-9) mol/L-4.0 x 10(-7) mol/L with the limit of detection (LOD) of 2.0 x 10(-10) mol/L, which is lower than the other reported methods. The proposed method is applied to determine catechol in reservoir water. The mean recoveries of 83.3%-99.0% and the relative standard deviations (RSDs) of 0.8%-2.2% were obtained. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 36 条
[21]   Energetic electrochemiluminescence of (9-fluorenyl)methanol induced by injection of hot electrons into aqueous electrolyte solution [J].
Kulmala, S ;
AlaKleme, T ;
Heikkila, L ;
Vare, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1997, 93 (17) :3107-3113
[22]   The carbon paste electrode encrusted with a microreactor as glucose biosensor [J].
Kulys, J .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :473-479
[23]   ELECTROOXIDATION OR REDUCTION OF ORGANIC COMPOUNDS INTO AQUEOUS SOLUTIONS USING CARBON PASTE ELECTRODE [J].
KUWANA, T ;
FRENCH, WG .
ANALYTICAL CHEMISTRY, 1964, 36 (01) :241-&
[24]   On-fiber derivatization of SPME extracts of phenol, hydroquinone and catechol with GC-MS detection [J].
Lourenço, ELB ;
Ferreira, A ;
Pinto, E ;
Yonamine, M ;
Farsky, SHP .
CHROMATOGRAPHIA, 2006, 63 (3-4) :175-179
[25]   A new type of hydrophilic carbon paste electrodes for biosensor manufacturing: Binder paste electrodes [J].
Parellada, J ;
Narvaez, A ;
Dominguez, E ;
Katakis, I .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (04) :267-275
[26]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES [J].
RAVICHANDRAN, K ;
BALDWIN, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 126 (1-3) :293-300
[27]   Application of carbon-paste electrode modified with iron phthalocyanine for voltammetric determination of epinephrine in the presence of ascorbic acid and uric acid [J].
Shahrokhian, Saeed ;
Ghalkhani, Masoumeh ;
Amini, Mohammad Kazem .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02) :669-675
[28]   Enhancement of electrochemical hot electron injection into electrolyte solutions at oxide-covered tantalum electrodes by thin platinum films [J].
Sung, YE ;
Bard, AJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) :9806-9811
[29]   Demonstration of electrochemical generation of solution-phase hot electrons at oxide-covered tantalum electrodes by direct electrogenerated chemiluminescence [J].
Sung, YE ;
Gaillard, F ;
Bard, AJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) :9797-9805
[30]   Hot electron-induced electrochemiluminescence of fluorescein in aqueous solution [J].
Suomi, J ;
Ylinen, T ;
Hakansson, M ;
Helin, M ;
Jiang, QH ;
Ala-Kleme, T ;
Kulmala, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 586 (01) :49-55