SewerSnort: A drifting sensor for in situ Wastewater Collection System gas monitoring

被引:13
作者
Lim, Jung Soo [1 ]
Kim, Jihyoung [1 ]
Friedman, Jonathan [2 ]
Lee, Uichin [3 ]
Vieira, Luiz [4 ]
Rosso, Diego
Gerla, Mario [1 ]
Srivastava, Mani B. [2 ]
机构
[1] UCLA CS, Los Angeles, CA USA
[2] UCLA EE, Los Angeles, CA USA
[3] KAIST KSE, Taejon, South Korea
[4] Univ Fed Minas Gerais, Dept Comp Sci, Belo Horizonte, MG, Brazil
基金
美国国家科学基金会;
关键词
Wastewater Collection System; Biochemical process; Electrochemical gas sensor; Received signal strength indicator based localization; Mobile sensing;
D O I
10.1016/j.adhoc.2011.01.016
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Biochemical reactions that occur in sewer pipes produce a considerable amount of hydrogen sulfide gas (H2S corrosive and poisonous), methane gas (CH4 explosive and a major climate change contributor), carbon dioxide (CO2 a major climate change contributor), and other volatile substances (collectively known as in-sewer gases). These toxic gases lead to contamination of natural environment, sewer pipe corrosion, costly operational expense, public safety issues, and legal disputes. In order to prevent biochemical reactions and to maintain healthy sewer pipes, frequent inspections are vital. Thus far, various schemes have been designed and developed to identify functional deficiencies in Wastewater Collection System (WCS). Nevertheless, the current inspection techniques are not for mapping the sewer gas concentration. In addition, because of such a harsh and hazardous environment a comprehensive sewer gases inspection has been prohibitively expensive. In this paper we propose SewerSnort, a low-cost, unmanned, fully automated in-sewer gas monitoring system. A sensor float is introduced at the upstream station and drifts down sewer pipeline, while the sensor float collects gas measurements along with location information of sampling points. At the end of the journey, the gas measurements are retrieved from the float and used to generate gas concentration to be used for maintenance or repair. The key innovations of SewerSnort are the fully automated, end-to-end monitoring solution and the low energy self localizing strategy. From the implementation standpoint, the key enablers are the float mechanical design that fits the sewer constraints and the embedded sensor design that matches the float form factor and complies with the tight energy constraints. Experiments based on a dry land emulator demonstrate the feasibility of the SewerSnort concept, in particular, the localization technique and the embedded sensor design. (c) 2011 Published by Elsevier B.V.
引用
收藏
页码:1456 / 1471
页数:16
相关论文
共 43 条
[1]  
A.S. of Civil Engineers, 2000, 82697010 CX USEPA
[2]   Navigation of an autonomous sewer inspection robot based on stereo camera images and laser scanner data [J].
Ahrary, Alireza ;
Tian, Li ;
Kamata, Sei-Ichiro ;
Ishikawa, Masumi .
INTERNATIONAL JOURNAL ON ARTIFICIAL INTELLIGENCE TOOLS, 2007, 16 (04) :611-625
[3]   Wireless underground sensor networks: Research challenges [J].
Akyildiz, Ian F. ;
Stuntebeck, Erich P. .
Ad Hoc Networks, 2006, 4 (06) :669-686
[4]  
[Anonymous], 2002, DAT MCP6041 600NA RA
[5]  
[Anonymous], 2008, THESIS U CALIFORNIA
[6]  
Bahl P., 2000, INFOCOM 00 TEL AV IS
[7]  
Churchill P., 1999, NEWEA J, V33, P57
[8]  
Datasheet, DAT EL H2S SENS 032
[9]  
Fan C.-Y., 2006, EPA600J03188 USEPA N
[10]  
Fenner R.A., 2000, Urban Water, V2, P343, DOI DOI 10.1016/S1462-0758(00)00065-0