Characterization of the distribution of rotational torque on electrorotation chips with 3D electrodes

被引:8
|
作者
Bahrieh, Garsha [1 ,3 ]
Ozgur, Ebru [3 ]
Koyuncuoglu, Aziz [3 ]
Erdem, Murat [2 ]
Gunduz, Ufuk [2 ]
Kulah, Haluk [1 ,3 ]
机构
[1] METU, Dept Elect & Elect Engn, Ankara, Turkey
[2] METU, Dept Biol, Ankara, Turkey
[3] METU MEMS Res & Applicat Ctr, Ankara, Turkey
关键词
Cell dielectric characterization; Electrorotation; Rotational torque; Rotating electric field; 3D electrodes; IMPEDANCE SPECTROSCOPY; DIELECTRIC-PROPERTIES; CELLS; DIELECTROPHORESIS; SEPARATION;
D O I
10.1002/elps.201500061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This is a study of in-plane and out-of-plane distribution of rotational torque (ROT-T) and effective electric field (EEF) on electrorotation (ER) devices with 3D electrodes using finite element modeling (FEM) and experimental method. The objective of this study is to investigate electrical characteristics of the ER devices with five different electrode geometries and obtain an optimum structure for ER experiments. Further, it provides a comparison between characteristics of the 3D electrodes and traditionally used 2D electrodes. 3D distributions of EEF were studied by the time-variant FEM. FEM results were verified experimentally by studying the rotation of biological cells. The results show that the variations of ROT-T and EEF over the measurement area of the devices are considerably large. This can potentially lead to misinterpretation of recorded data. Therefore, it is essential to specify the boundaries of the measurement area with minimum deviation from the central EEF. For this purpose, FE analyses were utilized to specify the optimal region. Thereby, with confining the measurements to these regions, the dependency of ROT-T on the spatial position of the particles can be eliminated. Comparisons have been made on the sustainability of the EEF and ROT-T distributions for each device, to find an optimum design. Analyses of the devices prove that utilization of the 3D electrodes eliminate irregularities of EEF and ROT-T along the z-axis. The Results show that triangular electrodes provide the highest sustainability for the in-plane ROT-T and EEF distribution, while the oblate elliptical and circular electrodes have the lowest variances along the z-axis.
引用
收藏
页码:1785 / 1794
页数:10
相关论文
共 50 条
  • [21] A 2D route to 3D computer chips
    Tania Roy
    Nature, 2024, 625 : 249 - 250
  • [22] Assembling 2D Blocks into 3D Chips
    Knechtel, Johann
    Markov, Igor L.
    Lienig, Jens
    ISPD 11: PROCEEDINGS OF THE 2011 ACM/SIGDA INTERNATIONAL SYMPOSIUM ON PHYSICAL DESIGN, 2011, : 81 - 88
  • [23] DESIGN AND DEVELOPMENT OF 3D ROTATIONAL BIOREACTOR FOR 3D CELL CULTURE
    Thunsiri, Kittiya
    Kumphune, Sarawut
    Wattanutchariya, Wassanai
    Rattanamongkhonkun, Kanya
    Chamroon, Chakkapong
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2023, 30 (02):
  • [24] Characterization of Alternate Power Distribution Methods for 3D Integration
    Zhang, David C.
    Swaminathan, Madhavan
    Keezer, David
    Telikepalli, Satyanarayana
    2014 IEEE 64TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2014, : 2260 - 2265
  • [25] 3D Architectures for Batteries and Electrodes
    Long, Jeffrey W.
    Dunn, Bruce
    Rolison, Debra R.
    White, Henry S.
    ADVANCED ENERGY MATERIALS, 2020, 10 (46)
  • [26] Planetary Torque in 3D Isentropic Disks
    Fung, Jeffrey
    Masset, Frederic
    Lega, Elena
    Velasco, David
    ASTRONOMICAL JOURNAL, 2017, 153 (03):
  • [27] Electrical and thermal characterization of a dielectrophoretic chip with 3D electrodes for cells manipulation
    Tay, Francis E. H.
    Yu, Liming
    Pang, Ah Ju
    Iliescu, Ciprian
    ELECTROCHIMICA ACTA, 2007, 52 (08) : 2862 - 2868
  • [28] 3D Force/Torque Characterization of Emergency Cricothyroidotomy Procedure using an Instrumented Scalpel
    Ryason, Adam
    Sankaranarayanan, Ganesh
    Butler, Kathryn L.
    DeMoya, Marc
    De, Suvranu
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2145 - 2148
  • [29] First electrical characterization of 3D detectors with electrodes of the same doping type
    Pozza, Alberto
    Boscardin, Maurizio
    Bosisio, Luciano
    Dalla Betta, Gian-Franco
    Piemonte, Claudio
    Ronchin, Sabina
    Zorzi, Nicola
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (02): : 317 - 321
  • [30] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308