An energy transfer method for 4D Monte Carlo dose calculation

被引:42
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [41] Towards real-time photon Monte Carlo dose calculation in the cloud
    Ziegenhein, Peter
    Kozin, Igor N.
    Kamerling, Cornelis Ph
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) : 4375 - 4389
  • [42] Superposition dose calculation incorporating Monte Carlo generated electron track kernels
    Keall, PJ
    Hoban, PW
    MEDICAL PHYSICS, 1996, 23 (04) : 479 - 485
  • [43] Monte Carlo based phase-space evolution for electron dose calculation
    Scora, D
    Faddegon, BA
    MEDICAL PHYSICS, 1997, 24 (02) : 177 - 187
  • [44] GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform
    Hissoiny, Sami
    Ozell, Benoit
    Bouchard, Hugo
    Despres, Philippe
    MEDICAL PHYSICS, 2011, 38 (02) : 754 - 764
  • [45] Monte Carlo photon beam modeling and commissioning for radiotherapy dose calculation algorithm
    Toutaoui, A.
    Chikh, S. Ait
    Khelassi-Toutaoui, N.
    Hattali, B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 833 - 837
  • [46] Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
    Huang, Jessie Y.
    Dunkerley, David
    Smilowitz, Jennifer B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 184 - 193
  • [47] Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams
    Vandervoort, Eric J.
    Tchistiakova, Ekaterina
    La Russa, Daniel J.
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2014, 41 (02) : 021711
  • [48] Development of a dose verification system for Vero4DRT using Monte Carlo method
    Ishihara, Yoshitomo
    Sawada, Akira
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Tanabe, Hiroaki
    Kaneko, Shuji
    Takayama, Kenji
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 160 - 172
  • [49] Time-resolved dosimetry for validation of 4D dose calculation in PBS proton therapy
    Kostiukhina, N.
    Palmans, H.
    Stock, M.
    Knopf, A.
    Georg, D.
    Knaeusl, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12)
  • [50] CALCULATION OF ABSORBED DOSE RATIOS USING CORRELATED MONTE-CARLO SAMPLING
    MA, CM
    NAHUM, AE