An energy transfer method for 4D Monte Carlo dose calculation

被引:42
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [31] Monte Carlo calculation of the neutron dose to a fetus at commercial flight altitudes
    Alves, M. C.
    Galeano, D. C.
    Santos, W. S.
    Hunt, John G.
    d'Errico, Francesco
    Souza, S. O.
    de Carvalho Junior, A. B.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 398 - 402
  • [32] DOSE CALCULATION ACCURACY OF THE MONTE CARLO ALGORITHM FOR CYBERKNIFE COMPARED WITH OTHER COMMERCIALLY AVAILABLE DOSE CALCULATION ALGORITHMS
    Sharma, Subhash
    Ott, Joseph
    Williams, Jamone
    Dickow, Danny
    MEDICAL DOSIMETRY, 2011, 36 (04) : 347 - 350
  • [33] Technical Note: Monte Carlo methods to comprehensively evaluate the robustness of 4D treatments in proton therapy
    Souris, Kevin
    Montero, Ana Barragan
    Janssens, Guillaume
    Di Perri, Dario
    Sterpin, Edmond
    Lee, John A.
    MEDICAL PHYSICS, 2019, 46 (10) : 4676 - 4684
  • [34] Monte Carlo shielding design with a large perturbation calculation method
    Tan, Wanbin
    Sun, Guangyao
    Long, Pengcheng
    Wu, Bin
    Song, Jing
    ANNALS OF NUCLEAR ENERGY, 2020, 138 (138)
  • [35] A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy
    Kry, Stephen F.
    Titt, Uwe
    Followill, David
    Poenisch, Falk
    Vassiliev, Oleg N.
    White, R. Allen
    Stovall, Marilyn
    Salehpour, Mohammad
    MEDICAL PHYSICS, 2007, 34 (09) : 3489 - 3499
  • [36] RayXpert V1: 3D software for the gamma dose rate calculation by Monte Carlo
    Peyrard, P. F.
    Pourrouquet, P.
    Dossat, C.
    Thomas, J. C.
    Chatry, N.
    Lavielle, D.
    Chatry, C.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [37] Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions
    Lin, Teh
    Wang, Lu
    Ma, C-M Charlie
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 99 - 104
  • [38] Applying graphics processor units to Monte Carlo dose calculation in radiation therapy
    Bakhtiari, M.
    Malhotra, H.
    Jones, M. D.
    Chaudhary, V.
    Walters, J. P.
    Nazareth, D.
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (02) : 120 - 122
  • [39] Monte Carlo dose calculation for photon and electron radiotherapy on dynamically deforming anatomy
    Zobrist, Bjorn
    Bertholet, Jenny
    Frei, Daniel
    Volken, Werner
    Amstutz, Florian
    Stampanoni, Marco F. M.
    Manser, Peter
    Fix, Michael K.
    Loebner, Hannes A.
    MEDICAL PHYSICS, 2025, 52 (02) : 1281 - 1292
  • [40] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Zhao, Yanqun
    Qi, Guohai
    Yin, Gang
    Wang, Xianliang
    Wang, Pei
    Li, Jian
    Xiao, Mingyong
    Li, Jie
    Kang, Shengwei
    Liao, Xiongfei
    RADIATION ONCOLOGY, 2014, 9