An energy transfer method for 4D Monte Carlo dose calculation

被引:42
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [21] Development of a deformable phantom for experimental verification of 4D Monte Carlo simulations in a deforming anatomy
    Gholampourkashi, Sara
    Cygler, Joanna E.
    Lavigne, Bernie
    Heath, Emily
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 81 - 90
  • [22] 4He dose- and track-averaged linear energy transfer: Monte Carlo algorithms and experimental verification
    Fattori, S.
    Petringa, G.
    Agosteo, S.
    Bortot, D.
    Conte, V
    Cuttone, G.
    Di Fini, A.
    Farokhi, F.
    Mazzucconi, D.
    Pandola, L.
    Petrovic, I
    Ristic-Fira, A.
    Rosenfeld, A.
    Weber, U.
    Cirrone, G. A. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (16):
  • [23] Experimental verification of a CT-based Monte Carlo dose-calculation method in heterogeneous phantoms
    Wang, L
    Lovelock, M
    Chui, CS
    MEDICAL PHYSICS, 1999, 26 (12) : 2626 - 2634
  • [24] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [25] Coarse-mesh adjoint biasing of a Monte Carlo dose calculation
    Pevey, R. E.
    Miller, L. F.
    Marshall, W. J.
    Townsend, L. W.
    Alvord, B.
    REACTOR DOSIMETRY: 12TH INTERNATIONAL SYMPOSIUM, 2008, 1490 : 252 - +
  • [26] Benchmarking Monte-Carlo dose calculation for MLC CyberKnife treatments
    Mackeprang P.-H.
    Vuong D.
    Volken W.
    Henzen D.
    Schmidhalter D.
    Malthaner M.
    Mueller S.
    Frei D.
    Kilby W.
    Aebersold D.M.
    Fix M.K.
    Manser P.
    Radiation Oncology, 14 (1)
  • [27] Evaluation of the eclipse electron Monte Carlo dose calculation for small fields
    Xu, Zhigang
    Walsh, Sarah E.
    Telivala, Tejas P.
    Meek, Allen G.
    Yang, Guozhen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 75 - 85
  • [28] Validation of RayStation Monte Carlo dose calculation algorithm for multiple LINACs
    Manco, Luigi
    Vega, Kevin
    Maffei, Nicola
    Gutierrez, Maria Victoria
    Cenacchi, Elisa
    Bernabei, Annalisa
    Bruni, Alessio
    D'angelo, Elisa
    Meduri, Bruno
    Lohr, Frank
    Guidi, Gabriele
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 109
  • [29] Calculation of radiation dose to the lens of the eye using Monte Carlo simulation
    Meriç, N
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 557 - 560
  • [30] Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning
    Chamberland, Eve
    Beaulieu, Luc
    Lachance, Bernard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 60 - 79