An energy transfer method for 4D Monte Carlo dose calculation

被引:42
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [1] Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer
    Matsugi K.
    Nakamura M.
    Miyabe Y.
    Yamauchi C.
    Matsuo Y.
    Mizowaki T.
    Hiraoka M.
    Radiological Physics and Technology, 2013, 6 (1) : 233 - 240
  • [2] Experimental verification of 4D Monte Carlo simulations of dose delivery to a moving anatomy
    Gholampourkashi, Sara
    Vujicic, Miro
    Belec, Jason
    Cygler, Joanna E.
    Heath, Emily
    MEDICAL PHYSICS, 2017, 44 (01) : 299 - 310
  • [3] Validation of 4D Monte Carlo dose calculations using a programmable deformable lung phantom
    Gholampourkashi, Sara
    Cygler, Joanna E.
    Lavigne, Bernie
    Heath, Emily
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 16 - 27
  • [4] A virtual photon energy fluence model for Monte Carlo dose calculation
    Fippel, M
    Haryanto, F
    Dohm, O
    Nüsslin, F
    Kriesen, S
    MEDICAL PHYSICS, 2003, 30 (03) : 301 - 311
  • [5] The regional Monte Carlo method: A dose calculation method based on accuracy requirement
    Woo, MK
    Scora, DJ
    Wong, E
    MEDICAL PHYSICS, 1998, 25 (10) : 1866 - 1871
  • [6] Fast Monte Carlo dose calculation in proton therapy
    Holmes, Jason
    Feng, Hongying
    Zhang, Lian
    Fix, Michael K.
    Jiang, Steve B.
    Liu, Wei
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17):
  • [7] Monte Carlo calculation of helical tomotherapy dose delivery
    Zhao, Ying-Li
    Mackenzie, M.
    Kirkby, C.
    Fallone, B. G.
    MEDICAL PHYSICS, 2008, 35 (08) : 3491 - 3500
  • [8] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273
  • [9] Monte carlo dose calculation in dental amalgam phantom
    Aziz, Mohd. Zahri Abdul
    Yusoff, A. L.
    Osman, N. D.
    Abdullah, R.
    Rabaie, N. A.
    Salikin, M. S.
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (03) : 150 - 155
  • [10] Using of PL-estimator of a dose at a point for dose calculation in heterogeneous media by Monte Carlo method
    Chupikin, D. A.
    Donskoy, E. N.
    Jourov, Y. V.
    Klimanov, V. A.
    Kosterev, V. V.
    Smirnov, V. V.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2072 - +