Defining the limits of application of duplex stainless steel coupled to carbon steel in oilfield environments

被引:12
|
作者
Griffiths, AJ [1 ]
Turnbull, A [1 ]
机构
[1] Natl Phys Lab, Ctr Mat Measurement & Technol, Teddington TW11 0LW, Middx, England
关键词
hydrogen; duplex stainless steel; galvanic coupling; permeation; slow strain rate;
D O I
10.5006/1.3290341
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Slow strain rate testing of solution-annealed (sigma(0.2) = 552 MPa [80 ksi]) and cold-worked (sigma(0.2) = 1,068 MPa [155 ksi]) 22%Cr duplex stainless steels (DSS) was conducted at different hydrogen charging currents in acid-brine solutions at 80degreesC (176degreesF). The charging currents and environments were designed to simulate coupling of DSS downhole tubulars to carbon steel casing, assuming a leak of production fluid into the annulus. In addition, a limited number of tests were conducted using less severe loading conditions, such as constant load and fluctuating load. To provide a framework for evaluating the results of the stress corrosion tests, hydrogen uptake was measured under equivalent conditions using primarily the electrochemical hydrogen permeation technique. Complementary tests were carried out using hot extraction techniques. In environments without hydrogen sulfide (H2S) at 80degreesC, there was no reduction in the plastic strain-to-failure of cold-worked DSS at charging currents typical of coupling to carbon steel (e.g., 100 muA/cm(2) [645 muA/in.(2)]). Addition of 1% H2S caused a reduction in the strain-to-failure at charging currents as small as 20,muA/cm(2) (129 muA/in.(2)). There was evidence of cracking on the surface of specimens in proof ring and ripple loading tests with 1% H2S and a charging current of 20 muA/cm(2), In H2S-saturated environments, the plastic strain-to-failure in slow strain rate tests was low at all charging currents and at open circuit. The cold-worked material was more susceptible to cracking than the solution-annealed material at all charging currents. For the same charging current density, the plastic strain-to-failure relative to oil was lower at 20degreesC (66degreesF) than at 80degreesC. The resistance to cracking did not correlate simply with bulk hydrogen uptake, as measured in the permeation tests. This suggests that the dominant factor is enhanced local hydrogen uptake at sites where the passive film, which acts as a barrier to hydrogen uptake, is ruptured.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 50 条
  • [21] Fatigue behaviour of sintered duplex stainless steel
    Tanski, T.
    Brytan, Z.
    Labisz, K.
    XVII INTERNATIONAL COLLOQUIUM ON MECHANICAL FATIGUE OF METALS (ICMFM17), 2014, 74 : 421 - 428
  • [22] Study of the failure of a duplex stainless steel valve
    Atxaga, G.
    Irisarri, A. M.
    ENGINEERING FAILURE ANALYSIS, 2009, 16 (05) : 1412 - 1419
  • [23] Effects of superplasticity in boronizing of duplex stainless steel
    Hasan, Rafidah
    Jauhari, Iswadi
    Ogiyama, Hiroyuki
    Ramdan, Rd. Dadan
    EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2, 2006, 326-328 : 1233 - +
  • [24] Investigation of the Hot Plasticity of Duplex Stainless Steel
    Lin Gang
    Zhang Zhi-xia
    Song Hong-wei
    Tong Jun
    Zhou Can-dong
    JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2008, 15 (06) : 83 - 86
  • [25] Study of precipitation in 2101 duplex stainless steel
    Zhang, W.
    Jiang, L. Z.
    Gao, J. Q.
    Song, H. M.
    Hu, J. C.
    MATERIALS SCIENCE AND TECHNOLOGY, 2010, 26 (05) : 515 - 521
  • [26] Tribocorrosion Influenced Pitting of a Duplex Stainless Steel
    Renner, Peter
    Chen, Yan
    Huang, Zhihao
    Raut, Ajinkya
    Liang, Hong
    LUBRICANTS, 2021, 9 (05)
  • [27] Investigation of the Hot Plasticity of Duplex Stainless Steel
    Gang Lin
    Zhi-xia Zhang
    Hong-wei Song
    Jun Tong
    Can-dong Zhou
    Journal of Iron and Steel Research International, 2008, 15 : 83 - 86
  • [28] Corrosion behavior of sensitized duplex stainless steel
    Torres, FJ
    Panyayong, W
    Rogers, W
    Velasquez-Plata, D
    Oshida, Y
    Moore, BK
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1998, 8 (01) : 25 - 36
  • [29] Investigation of the Hot Plasticity of Duplex Stainless Steel
    LIN Gang1
    2.School of Material Science and Engineering
    Journal of Iron and Steel Research(International), 2008, (06) : 83 - 86
  • [30] Deformation and recrystallization textures in duplex stainless steel
    de Lima, NB
    de Lima, LMFG
    Reick, W
    Padilha, AF
    TEXTURES OF MATERIALS, PTS 1 AND 2, 2002, 408-4 : 1353 - 1358