Broadband Minimum Variance Beamforming for Ultrasound Imaging

被引:196
|
作者
Holfort, Iben Kraglund [1 ]
Gran, Fredrik [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] CN ReSound AS, Ballerup, Denmark
关键词
D O I
10.1109/TUFFC.2009.1040
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A minimum variance (MV) approach for near-field beamforming of broadband data is proposed. The approach is implemented in the frequency domain, and it provides a set of adapted, complex apodization weights for each frequency subband. The performance of the proposed MV beamformer is tested on simulated data obtained using Field II. The method is validated using synthetic aperture data and data obtained from a plane wave emission. Data for 13 point targets and a circular cyst with a radius of 5 mm are simulated. The performance of the MV beamformer is compared with delay-an sum (DS) using boxcar weights and Harming weights and is quantified by the full width at half maximum (FWHM) and the peak-side-lobe level (PSL). Single emission {DS boxcar, DS Harming, MV} provide a PSL of {-16, -36, -49} dB and a FWHM of {0.79, 1.33, 0.08} mm. Using all 128 emissions, {DS boxcar, DS Harming, MV} provides a PSL of {-32, -49, -65} dB, and a FWHM of {0.63, 0.97, 0.08} rum. The contrast of the beamformed single emission responses of the circular cyst was calculated as {-18, -37, -40} dB. The simulations have shown that the frequency subband MV beamformer provides a significant increase in lateral resolution compared with DS, even when using considerably fewer emissions. An increase in resolution is seen when using only one single emission. Furthermore, the effect of steering vector errors is investigated. The steering vector errors are investigated by applying an error of the sound speed estimate to the ultrasound data. As the error increases, it is seen that the MV beamformer is not as robust compared with the DS beamformer with boxcar an Harming weights. Nevertheless, it is noted that the DS does not outperform the MV beamformer. For errors of 2% and 4% of the correct value, the FWHM are {0.81, 1.25, 0.34) mm and {0.89, 1.44, 0.46} min, respectively.
引用
收藏
页码:314 / 325
页数:12
相关论文
共 50 条
  • [1] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sayed Mahmoud Sakhaei
    Seyede Elham Shamsian
    Journal of Medical Ultrasonics, 2018, 45 : 17 - 24
  • [2] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sakhaei, Sayed Mahmoud
    Shamsian, Seyede Elham
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (01) : 17 - 24
  • [3] Deep Learning Based Minimum Variance Beamforming for Ultrasound Imaging
    Zhuang, Renxin
    Chen, Junying
    SMART ULTRASOUND IMAGING AND PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, SUSI 2019, PIPPI 2019, 2019, 11798 : 83 - 91
  • [4] Minimum variance adaptive beamforming applied to medical ultrasound imaging
    Synnevag, JF
    Austeng, A
    Holm, S
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1199 - 1202
  • [5] Phase Aberration Correction in Minimum Variance Beamforming of Ultrasound Imaging
    Ziksari, Mahsa Sotoodeh
    Asl, Babak Mohammadzadeh
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 23 - 26
  • [6] Benefits of Minimum-Variance Beamforming in Medical Ultrasound Imaging
    Synnevag, Johan-Fredrik
    Austeng, Andreas
    Holm, Sverre
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (09) : 1868 - 1879
  • [7] Multibeam minimum variance beamforming for ring array ultrasound imaging
    Zhang, Hao
    Zhu, Yunhao
    Zhou, Bowen
    Liu, Songde
    He, Nianan
    Tian, Chao
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13):
  • [8] Adaptive minimum variance beamforming combined with phase coherence imaging for ultrasound imaging
    Xu, Mengling
    Chen, Yimin
    Ding, Mingyue
    Ming Yuchi
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [9] Minimum variance beamforming for high frame-rate ultrasound imaging
    Holfort, Then Kraglund
    Gran, Fredrik
    Jensen, Jorgen Arendt
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1541 - 1544
  • [10] Minimum Variance Beamforming Applied to Ultrasound Imaging With a Partially Shaded Aperture
    Mehdizadeh, Saeed
    Austeng, Andreas
    Johansen, Tonni F.
    Holm, Sverre
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) : 683 - 693