Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom

被引:11
作者
Tzamicha, E. [1 ]
Yakoumakis, E. [1 ]
Tsalafoutas, I. A. [4 ]
Dimitriadis, A. [1 ]
Georgiou, E. [1 ]
Tsapaki, V. [3 ]
Chalazonitis, A. [2 ]
机构
[1] Univ Athens, Dept Med Phys, GR-10679 Athens, Greece
[2] Alexandra Gen Hosp, Dept Radiol, Athens, Greece
[3] Konstantopoulio Gen Hosp Nea Ionia, Dept Med Phys, Attiki, Greece
[4] Athens Gen Anticanc Oncol Hosp Agios Savvas, Athens, Greece
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2015年 / 31卷 / 07期
关键词
CEDM; Dosimetry; Monte Carlo; Breast; Mammography; Voxel phantom; MASH FEMALE; BREAST; FASH; UK;
D O I
10.1016/j.ejmp.2015.03.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom. Methods: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy). Results: For breast phantoms of 2.0-8.0 cm thick and 0.1-100% glandular fraction, CC view acquisition, from AEC settings, can result in a mean glandular dose of 0.450 +/- 0.022 mGy - 2.575 +/- 0.033 mGy for low energy images and 0.061 +/- 0.021 mGy - 0.232 +/- 0.033 mGy for high energy images. In MLO view acquisition mean glandular dose values ranged between 0.488 +/- 0.007 mGy - 2.080 +/- 0.021 mGy for low energy images and 0.065 +/- 0.012 mGy - 0.215 +/- 0.010 mGy for high energy images. Conclusion: The low kV part of contrast enhanced digital mammography is the main contributor to total mean glandular breast dose. The results of this study can be used to provide an estimated mean glandular dose for individual cases. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2002, ICRP PUBL
[2]  
[Anonymous], 2007, Technical Reports Series, V457
[3]  
[Anonymous], ANN ICRP
[4]   Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data [J].
Boone, JM .
MEDICAL PHYSICS, 2002, 29 (05) :869-875
[5]   Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection [J].
Cassola, V. F. ;
Kramer, R. ;
Brayner, C. ;
Khoury, H. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) :4399-4430
[6]   FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy [J].
Cassola, V. F. ;
de Melo Lima, V. J. ;
Kramer, R. ;
Khoury, H. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :133-162
[7]  
Cranley K., 1997, CATALOGUE DIAGNOSTIC
[8]   Estimation of mean glandular dose for contrast enhanced digital mammography: factors for use with the UK, European and IAEA breast dosimetry protocols [J].
Dance, D. R. ;
Young, K. C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09) :2127-2137
[9]   Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols [J].
Dance, D. R. ;
Young, K. C. ;
van Engen, R. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (14) :4361-4372
[10]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240