Identification of Ulnar Artery Perforators Using Color Doppler Ultrasonography

被引:3
作者
Ishiko, Megumi [1 ]
Yano, Koichi [2 ]
Onode, Ema [3 ]
Takamatsu, Kiyohito [1 ]
机构
[1] Yodogawa Christians Hosp, Dept Orthopaed Surg, Osaka, Japan
[2] Seikeikai Hosp, Dept Orthopaed Surg, Osaka, Japan
[3] Osaka City Univ, Dept Orthopaed Surg, Grad Sch Med, Osaka, Japan
关键词
perforator flap; ulnar artery perforator; color Doppler ultrasonography; FLAP PERFORATORS; RECONSTRUCTION; FOREARM; BRANCHES; ANATOMY; SKIN;
D O I
10.1055/s-0040-1713601
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The ulnar artery perforator (UAP) flap, which is hairless, thin, and pliable, has been used for the reconstruction of soft tissues from the finger to the elbow. Preoperative planning is essential for a perforator flap surgery, and there are some tests to identify perforators. Color Doppler ultrasonography (US) with a high-frequency transducer helps in detecting decreased flow in smaller vessels, such as perforators. The purpose of this study was to determine the anatomical locations and origins of perforators arising from the ulnar artery using color Doppler US in healthy volunteers. Methods Forty forearms of 20 healthy volunteers were included in the study. Perforators arising from the ulnar artery, within 100mm proximal to the pisiform, were investigated using color Doppler US with a high-frequency transducer. Results A total of 205 perforators were identified. On comparing the locations in each 20mm section from the pisiform, the largest number of perforators was 58 (28%), within 20mm proximal to the pisiform. The axial view demonstrated 44 (21%), 64 (31%), 32 (16%), and 65 (32%) perforators in the radial, ulnar, superficial, and deep aspects of the ulnar artery, respectively. Fifty-two and 28 essential perforators were supplied by the UAPs arising from the superficial and ulnar aspect within 20mm proximal to the pisiform and between 21 and 40mm proximal to the pisiform, respectively, while elevating the UAP flap. Conclusion This is the first study to assess the UAP using color Doppler US. Identification of UAP using color Doppler US can be used as a preoperative assessment for reliable elevation of a UAP flap.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 26 条
[1]  
Becker C, 1988, PLAST CHIR, V20, P180
[2]   The neurocutaneous flap based on the dorsal branches of the ulnar artery and nerve: A new flap for extensive reconstruction of the hand [J].
Bertelli, JA ;
Pagliei, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (06) :1537-1543
[3]  
Blondeel P N, 2013, PERFORATOR FLAPS ANA, P367
[4]   Reliability of Color Doppler Ultrasound Imaging for the Assessment of Anterolateral Thigh Flap Perforators: A Prospective Study of 30 Perforators [J].
Debelmas, Alexandre ;
Camuzard, Olivier ;
Aguilar, Paola ;
Qassemyar, Quentin .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 141 (03) :762-766
[5]   PREOPERATIVE IDENTIFICATION OF PERFORATING VESSELS TO THE SKIN BY COLOR DUPLEX IMAGING [J].
HALLOCK, GG ;
BROWN, CL ;
DESANTIS, MJ .
JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (04) :263-266
[6]   Cutaneous perforators of the forearm - Anatomic shady for clinical application [J].
Hwang, K ;
Hwang, JH ;
Jung, CY ;
Won, HS ;
Chung, IH .
ANNALS OF PLASTIC SURGERY, 2006, 56 (03) :284-288
[7]  
Kehrer A, 2019, J PLAST RECONSTR AES
[8]   Feasibility study of preoperative microvessel evaluation and characterization in perforator flaps using various modes of color-coded duplex sonography (CCDS) [J].
Kehrer, Andreas ;
Lonic, Daniel ;
Heidekrueger, Paul ;
Bosselmann, Talia ;
Taeger, Christian D. ;
Philipp, Lamby ;
Kehrer, Michael ;
Jung, Ernst Michael ;
Prantl, Lukas ;
Platz Batista da Silva, Natascha .
MICROSURGERY, 2020, 40 (07) :750-759
[9]  
Kimura T, 2017, PRS-GLOB OPEN, V5, DOI 10.1097/GOX.0000000000001550
[10]   Blood flow dynamics and sensitivity in breasts after reconstruction with DIEP-flap [J].
Klasson, Stina ;
Svensson, Karin ;
Wollmer, Per ;
Velander, Patrik ;
Svensson, Henry .
JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2014, 48 (06) :407-411