Left ventricular lead proximity to an akinetic segment and impact on outcome of cardiac resynchronization therapy

被引:21
|
作者
Arzola-Castaner, Daniel [1 ]
Taub, Cynthia [1 ]
Heist, E. Kevin [1 ]
Fan, Dali [1 ]
Haelewyn, Kyle [1 ]
Mela, Theofanie [1 ]
Picard, Michael H. [1 ]
Ruskin, Jeremy N. [1 ]
Singh, Jagmeet P. [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Cardiac Arrhythmia Serv,Cardiac Ultrasound Lab, Boston, MA 02114 USA
关键词
cardiac resynchronization therapy; hemodynamic response; heart failure; cardiac pacing;
D O I
10.1111/j.1540-8167.2006.00480.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Previous studies report that the optimal pacing site for cardiac resynchronization therapy (CRT) is along the left ventricular (LV) lateral and postero-lateral (PL) wall. However, little is known regarding whether pacing over an akinetic site impacts the contractile response and long-term outcome from CRT. Methods and Results: A total of 38 patients with ischemic cardiomyopathy were studied for their acute hemodynamic and 12-month clinical response to CRT. The intraindividual percentage change in dP/dt (%Delta dP/dt), over baseline, was derived from the mitral regurgitation (MR) Doppler profile with CRT on versus off. Two-dimensional echocardiography was used for myocardial segmentation and determinination of akinetic sites. LV lead implant site was determined using angiographic and radiographic data and categorized as being "on" (group 1) or "off" (group 2) an akinetic site. Long-term response was measured as a combined endpoint of hospitalization for heart failure and/or all cause mortality at 12 months. Time to primary endpoint was estimated by the Kaplan-Meier method. Clinical characteristics and acute hemodynamic response was similar in both (group 1 [n = 14]; %Delta dP/dt 48.8 +/- 67.4% vs group 2 [n = 24]; %Delta dP/dt 32.2 +/- 40.1%, P = 0.92). No difference in long-term outcome was observed (P = 0.59). In contrast, lead placement in PL or mid-lateral (ML) positions was associated with a better acute hemodynamic response when compared to antero-lateral (AL) positions (PL, %Delta dP/dt 45.7 +/- 50.7% and ML, %Delta dP/dt 45.1 +/- 58.8% vs AL, %Delta dP/dt 2.9 +/- 30.9%, respectively, P = 0.014). Conclusion: LV lead proximity to an akinetic segment does not impact acute hemodynamic or 12-month clinical response to CRT.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 50 条
  • [21] The anatomic and electrical location of the left ventricular lead predicts ventricular arrhythmia in cardiac resynchronization therapy
    Friedman, Daniel J.
    Upadhyay, Gaurav A.
    Altman, Robert K.
    Orencole, Mary
    Barrett, Conor D.
    Mela, Theofanie
    Heist, E. Kevin
    Singh, Jagmeet P.
    HEART RHYTHM, 2013, 10 (05) : 668 - 675
  • [22] Preoperative CT of cardiac veins for planning left ventricular lead placement in cardiac resynchronization therapy
    Markstad, Hanna
    Bakos, Zoltan
    Ostenfeld, Ellen
    Geijer, Mats
    Carlsson, Marcus
    Borgquist, Rasmus
    ACTA RADIOLOGICA, 2019, 60 (07) : 859 - 865
  • [23] Impact of baseline left ventricular volume on left ventricular reverse remodeling after cardiac resynchronization therapy
    Galloo, Xavier
    Stassen, Jan
    Hirasawa, Kensuke
    Chimed, Surenjav
    Cosyns, Bernard
    Marsan, Nina Ajmone
    Delgado, Victoria
    van der Bijl, Pieter
    Bax, Jeroen J.
    HEART RHYTHM, 2022, 19 (06) : 927 - 936
  • [24] Impact of paced left ventricular dyssynchrony on left ventricular reverse remodeling after cardiac resynchronization therapy
    Gauthey, Anais
    Willemen, Erik
    Lumens, Joost
    Ploux, Sylvain
    Bordachar, Pierre
    Ritter, Philippe
    Prinzen, Frits W.
    Lejeune, Sibille
    Pouleur, Anne-Catherine
    Garnir, Quentin
    Marchandise, Sebastien
    Scavee, Christophe
    Wauters, Aurelien
    De Waroux, Jean-Benoit Le Polain
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (02) : 494 - 502
  • [25] Clinical impact of an additional left ventricular lead in cardiac resynchronization therapy nonresponders: The V3 trial
    Bordachar, Pierre
    Gras, Daniel
    Clementy, Nicolas
    Defaye, Pascal
    Mondoly, Pierre
    Boveda, Serge
    Anselme, Frederic
    Klug, Didier
    Piot, Olivier
    Sadoul, Nicolas
    Babuty, Dominique
    Leclercq, Christophe
    HEART RHYTHM, 2018, 15 (06) : 870 - 876
  • [26] Impact of radiocontrast use during left ventricular pacemaker lead implantation for cardiac resynchronization therapy
    Tester, Gregory A.
    Noheria, Amit
    Carrico, Heather L.
    Mears, Jennifer A.
    Cha, Yong-Mei
    Powell, Brian D.
    Friedman, Paul A.
    Rea, Robert F.
    Hayes, David L.
    Asirvatham, Samuel J.
    EUROPACE, 2012, 14 (02): : 243 - 248
  • [27] Left ventricular lead placement in cardiac resynchronization therapy: where and how?
    Khan, Fakhar Zaman
    Virdee, Munmohan Singh
    Fynn, Simon Patrick
    Dutka, David Paul
    EUROPACE, 2009, 11 (05): : 554 - 561
  • [28] QRS morphology, left ventricular lead location, and clinical outcome in patients receiving cardiac resynchronization therapy
    Kandala, Jagdesh
    Upadhyay, Gaurav A.
    Altman, Robert K.
    Parks, Kimberly A.
    Orencole, Mary
    Mela, Theofanie
    Heist, E. Kevin
    Singh, Jagmeet P.
    EUROPEAN HEART JOURNAL, 2013, 34 (29) : 2252 - 2262
  • [29] The impact of left ventricular size on response to cardiac resynchronization therapy
    Rickard, John
    Brennan, Danielle M.
    Martin, David O.
    Hsich, Eileen
    Tang, W. H. Wilson
    Lindsay, Bruce D.
    Starling, Randall C.
    Wilkoff, Bruce L.
    Grimm, Richard A.
    AMERICAN HEART JOURNAL, 2011, 162 (04) : 646 - 653
  • [30] Clinical outcome of cardiac resynchronization therapy in patients randomized to an active fixation bipolar left ventricular lead versus a passive quadripolar lead
    Keilegavlen, Havard
    Schuster, Peter
    Hovstad, Thomas
    Faerestrand, Svein
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2021, 55 (03) : 153 - 159