Structural Health Monitoring using an Embedded PZT-FBG Ultrasonic Sensor Array

被引:0
|
作者
Botsev, Y. [1 ]
Arad, E. [1 ]
Tur, M. [1 ]
Kressel, I. [2 ]
Ben-Simon, U. [2 ]
Gail, S. [3 ]
Osmont, D. [4 ]
机构
[1] Tel Aviv Univ, Sch Elect Engn, IL-69978 Tel Aviv, Israel
[2] Ben Gurion Int Airport, IAI Engn Div, IR-70100 Tel Aviv, Israel
[3] Consultant, Tel Aviv, Israel
[4] Off Natl Etud & Rech Aerosp, F-92320 Chatillon, France
来源
PROCEEDINGS OF THE FOURTH EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING 2008 | 2008年
关键词
Bragg grating; ultrasonic; structural health monitoring; Lamb Wave; BRAGG GRATING SENSORS; DAMAGE DETECTION; FIBER;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
An advanced structural integrity methodology, based on the integration of PZT actuators/sensors and Fiber Bragg Gratings (FBGs) ultrasonic sensors, for structural health monitoring applications, is proposed and demonstrated, with emphasis on patched repairs.
引用
收藏
页码:649 / 656
页数:8
相关论文
共 50 条
  • [41] PZT Sensors and Their Application in Structural Health Monitoring
    Xuan, Sun
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 669 - 675
  • [42] Polarization Maintaining Photonic Crystal Fiber sensor embedded in carbon composite for structural health monitoring
    Thakur, Harneet V.
    Nalawade, Sandipan M.
    MEASUREMENT, 2011, 44 (05) : 847 - 851
  • [43] Lamb wave Structural Health Monitoring Using a Hybrid PZT-Laser Vibrometer Approach
    Yu, Lingyu
    Tian, Zhenhua
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2013, 12 (5-6): : 469 - 483
  • [44] Numerical analysis for structural health monitoring of a damaged composite panel using PZT actuators and sensors
    Nagabhushana, A.
    Spiegel, M.
    Adu, S.
    Hayes, N.
    Paul, D.
    Trivedi, K.
    Fairbee, B.
    Zheng, H.
    Gerrity, A.
    Kotru, S.
    Roy, S.
    Barkey, M.
    Burkett, S. L.
    SMART SENSOR PHENOMENA, TECHNOLOGY, NETWORKS, AND SYSTEMS INTEGRATION 2012, 2012, 8346
  • [45] Structural health monitoring of slab-column connections using FBG sensors
    Rizk, E.
    Marzouk, H.
    Hussein, A.
    Gu, X.
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2012, 2 (01) : 17 - 27
  • [46] Thermal Characteristics of FBG Sensors at Cryogenic Temperatures for Structural Health Monitoring
    Kang, Donghoon
    Kim, Heon-Young
    Kim, Dae-Hyun
    Park, Seunghee
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2016, 17 (01) : 5 - 9
  • [47] Structural Health Monitoring Using Wireless Sensor Networks: A Comprehensive Survey
    Noel, Adam B.
    Abdaoui, Abderrazak
    Elfouly, Tarek
    Ahmed, Mohamed Hossam
    Badawy, Ahmed
    Shehata, Mohamed S.
    IEEE COMMUNICATIONS SURVEYS AND TUTORIALS, 2017, 19 (03) : 1403 - 1423
  • [48] High-directivity array of ultrasonic micro sensor using PZT thin film on Si diaphragm
    Yamashita, K
    Katata, H
    Okuyama, N
    Miyoshi, H
    Kato, G
    Aoyagi, S
    Suzuki, Y
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 114 - 117
  • [49] Structural monitoring for the cyclic behaviour of concrete tunnel lining sections using FBG sensors
    Bursi, Oreste S.
    Tondini, Nicola
    Fassin, Manuel
    Bonelli, Alessio
    STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (04) : 749 - 763
  • [50] Health monitoring of steel structures using surface mountable and detachable PZT sensor
    Singh, Sachin Kumar
    Shanker, Rama
    Ranjan, Achint
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2024, 35 (04) : 380 - 392