Supraspinatus tendon repair using anchors: a biomechanical evaluation in the rabbit

被引:10
作者
Louati, Hakim [1 ]
Uhthoff, Hans K. [2 ,3 ]
Culliton, Kathryn [4 ]
Laneuville, Odette [5 ]
Lapner, Peter [3 ]
Trudel, Guy [6 ,7 ]
机构
[1] Univ Ottawa, Bone & Joint Res Lab, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa Hosp, Res Inst, Bone & Joint Res Lab, Ottawa, ON, Canada
[3] Univ Ottawa, Ottawa Hosp, Res Inst, Div Orthopaed Surg, Ottawa, ON, Canada
[4] Univ Ottawa, Div Orthopaed Surg, Orthopaed Biomech Lab, Ottawa, ON, Canada
[5] Univ Ottawa, Dept Biol, Ottawa, ON, Canada
[6] Univ Ottawa, Dept Med, Div Phys Med & Rehabil, Bone & Joint Res Lab, Ottawa, ON, Canada
[7] Ottawa Hosp, Rehabil Ctr, Div Phys Med & Rehabil, 505 Smyth Rd, Ottawa, ON K1H 8M2, Canada
基金
加拿大健康研究院;
关键词
Rotator cuff; Biomechanical; Channeling; Supraspinatus tendon; Rabbit; Decortication; ROTATOR CUFF REPAIR; BONY TROUGH; TEARS; STRENGTH; INTEGRITY; FIXATION; TISSUES; CELLS; MODEL; HEAL;
D O I
10.1186/s13018-018-0773-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Arthroscopic rotator cuff repairs are mostly secured with suture anchors and often supplemented by footprint decortication. The objectives of this study were to characterize the strength of bone-tendon healing following anchor repair and assess the effect of channeling the supraspinatus (SSP) humeral footprint 1 week ahead of reattachment surgery. Methods: One hundred twelve rabbits underwent unilateral detachment of one SSP tendon and were randomly assigned to two groups: channeling the footprint at time of detachment and no channeling. One week later, reattachment was performed using an anchor. The repaired and contralateral shoulders were harvested at 0, 1, 2, or 4 weeks after repair and mechanically tested to failure. Outcome measures included load at failure, stiffness, and site of failure. Results: Anchor fixation had a mean load at failure of 81 +/- 32 N and a stiffness of 27 +/- 9 N/mm immediately after repair compared to 166 +/- 47 N and 66 +/- 13 N/mm in the contralateral (both p < 0.05). Mechanical recovery of the reattached SSP tendon was achieved after 4 weeks (221 +/- 73 N, 206 +/- 59 N, and 198 +/- 49 N in the channeling, no channeling, and contralateral groups, respectively, p > 0.05). The dominant site of failure shifted from the footprint at 0/1 week to bone avulsion/mid-substance tear at 4 weeks (p < 0.05). There were no differences in outcomes between the channeling and no channeling groups. Conclusions: This study is the first of its kind to provide quantitative data on the mechanical properties of the enthesis following anchor repair in a rabbit model. Anchor repair led to rapid and complete restoration of SSP mechanical properties. Further evidence is needed before recommending channeling ahead of repair surgery.
引用
收藏
页数:8
相关论文
共 28 条
[1]  
Apostolakos John, 2014, Muscles Ligaments Tendons J, V4, P333
[2]   Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study [J].
Bishop, Julie ;
Klepps, Steven ;
Lo, Ian K. ;
Bird, Justin ;
Gladstone, James N. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) :290-299
[3]   Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[4]   The Evolution of Suture Anchors in Arthroscopic Rotator Cuff Repair [J].
Denard, Patrick J. ;
Burkhart, Stephen S. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (09) :1589-1595
[5]  
Edelstein L, 2011, J MUSCULOSKEL NEURON, V11, P150
[6]   Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique [J].
El-Azab, H. ;
Buchmann, S. ;
Beitzel, K. ;
Waldt, S. ;
Imhoff, Andreas B. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (12) :1730-1737
[7]   A biomechanical and histological comparison of the suture bridge and conventional double-row techniques of the repair of full-thickness rotator cuff tears in a rabbit model [J].
Fei, Wenyong ;
Guo, Weichun .
BMC MUSCULOSKELETAL DISORDERS, 2015, 16
[8]   Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair [J].
Frank, Joshua B. ;
ElAttrache, Neal S. ;
Dines, Joshua S. ;
Blackburn, Allie ;
Crues, John ;
Tibone, James E. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (08) :1496-1503
[9]   MECHANICAL STRENGTH OF REPAIRS OF THE ROTATOR CUFF [J].
GERBER, C ;
SCHNEEBERGER, AG ;
BECK, M ;
SCHLEGEL, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :371-380
[10]   Arthroscopic Treatment of Rotator Cuff Disease [J].
Jarrett, Claudius D. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (09) :1541-1552