Condition monitoring methods applied to degradation of chlorosulfonated polyethylene cable jacketing materials

被引:28
作者
Gillen, KT [1 ]
Assink, R [1 ]
Bernstein, R [1 ]
Celina, M [1 ]
机构
[1] Sandia Natl Labs, Organ Mat Dept, Albuquerque, NM 87185 USA
关键词
aging; chlorosulfonated polyethylene; condition monitoring; modulus; NMR relaxation; solvent uptake;
D O I
10.1016/j.polymdegradstab.2005.09.002
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Three promising polymer material condition monitoring (CM) methods were applied to eight commercial chlorosulfonated polyethylene cable jacket materials aged under both elevated temperature and high-energy radiation conditions. The CM methods examined, cross-sectional modulus profiling, solvent uptake and NMR T-2 relaxation time measurements of solvent-swelled samples, are closely related since they are all strongly influenced by the changes in overall crosslink density of the materials. Each approach was found to correlate well with ultimate tensile elongation measurements, the most widely used method for following degradation of elastomeric materials. In addition approximately universal failure criteria were found to be applicable for the modulus profiling and solvent uptake measurements, independent of the CSPE material examined and its degradation environment. For an arbitrarily assumed elongation "failure" criterion of 50% absolute, the CSPE materials typically reached "failure" when the modulus increased to similar to 35 MPa and the uptake factor in p-xylene decreased to similar to 1.6. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1273 / 1288
页数:16
相关论文
共 31 条
[1]   Condition assesment of cable insulation systems in operating nuclear power plants [J].
Anandakumaran, K ;
Seidl, W ;
Castaldo, PV .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (03) :376-384
[2]   ASSESSMENT OF OXIDATIVE THERMAL-DEGRADATION OF CROSS-LINKED POLYETHYLENE AND ETHYLENE PROPYLENE RUBBER CABLE INSULATION [J].
ANANDAKUMARAN, K ;
STONKUS, DJ .
POLYMER ENGINEERING AND SCIENCE, 1992, 32 (18) :1386-1393
[3]  
ANANDAKUMARAN K, 1995, TR105581 EPRI
[4]   Monitoring the degradation of a thermally aged EPDM terpolymer by 1H NMR relaxation measurements of solvent swelled samples [J].
Assink, RA ;
Gillen, KT ;
Sanderson, B .
POLYMER, 2002, 43 (04) :1349-1355
[5]   Condition monitoring of a thermally aged hydroxy-terminated polybutadiene (HTPB)/isophorone diisocyanate (IPDI) elastomer by nuclear magnetic resonance cross-polarization recovery times [J].
Assink, RA ;
Lang, DP ;
Celina, M .
JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 81 (02) :453-459
[6]  
ASSINK RA, 2003, POLYM NEWS, V28, P102
[7]  
BASEDEN GA, 1987, RUBBER TECHNOLOGY, P360
[8]   AN ANALYSIS OF THE DUROMETER INDENTATION [J].
BRISCOE, BJ ;
SEBASTIAN, KS .
RUBBER CHEMISTRY AND TECHNOLOGY, 1993, 66 (05) :827-836
[9]  
BUSTARD L., 1994, TR103841 EPRI
[10]   Oxidation profiles of thermally aged nitrile rubber [J].
Celina, M ;
Wise, J ;
Ottesen, DK ;
Gillen, KT ;
Clough, RL .
POLYMER DEGRADATION AND STABILITY, 1998, 60 (2-3) :493-504