Research On Adhesive Property of Reinforced Concrete Sructure Strengthened With Near-surface Mounted FRP Bars

被引:0
|
作者
Xu Yongfeng
Guo Weitong
He Tengfei
机构
来源
关键词
FRP bars; reinforced concrete beam; near surface mounted;
D O I
10.4028/www.scientific.net/AMM.351-352.980
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Now concrete beams reinforced with near surface mounted FRP bars has been researched at home and abroad. This article research the Bearing capacity of concrete beams reinforced with near surface mounted FRP bars by test, and also, Immunobead binding test, infer the calculation formula of ultimate bearing capacity with near surface mounted some bars base on the the single bar.
引用
收藏
页码:980 / 985
页数:6
相关论文
共 50 条
  • [31] Reliability-based assessment of bond strength models for near-surface mounted FRP bars and strips to concrete
    Aghamohammadi, Reza
    Nasrollahzadeh, Kourosh
    Mofidi, Amir
    Gosling, Peter
    COMPOSITE STRUCTURES, 2021, 272
  • [32] Laboratory Evaluation of Concrete Bridge Girders Flexural Strengthened with Near-surface Mounted Titanium Alloy Hooked Bars
    Islam, Md Aminul
    Sener, Kadir C.
    Schindler, Anton K.
    TRANSPORTATION RESEARCH RECORD, 2024, 2678 (11) : 547 - 562
  • [33] Reinforced concrete columns strengthened with near-surface mounted and hybrid FRP under compression with or without eccentricity: Experimental study and finite element modeling
    Shayanfar, Mohsen Ali
    Ghanooni-Bagha, Mohammad
    Afzali, Solmaz
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [34] Flexural Testing of Reinforced Concrete Beams Strengthened with Near-Surface Mounted Titanium-Alloy Hooked Bars to Evaluate Member and Bond Strength
    Aguilar, Victor
    Flowers, Jack C.
    Islam, Md Aminul
    Sener, Kadir
    Schindler, Anton K.
    TRANSPORTATION RESEARCH RECORD, 2025,
  • [35] Calculation of Flexural Capacity of Steel Reinforced Concrete Beams Strengthened with Near-Surface Mounted CFRP Rods
    Chen, Wei Hua
    Wu, Mei Qin
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 1031 - +
  • [36] Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars
    Tang, W. C.
    Balendran, R. V.
    Nadeem, A.
    Leung, H. Y.
    BUILDING AND ENVIRONMENT, 2006, 41 (10) : 1381 - 1393
  • [37] Near-surface Mounted Technology in Strengthening Reinforced Concrete Beam
    Dazulhisham, Muhammad Adam Syahmi
    Halim, Muhammad Arif Ikmal Abdul
    Goh, Lyn Dee
    INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 2024, 15 (01): : 211 - 225
  • [38] Concrete cover separation of reinforced concrete beams strengthened with near-surface mounted method: Mechanics based design approach
    Shukri, Ahmad Azim
    Ibrahim, Zainah
    Hashim, Huzaifa
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (07) : 1739 - 1754
  • [39] The bond and flexural strengthening of reinforced concrete elements strengthened with near surface mounted prestressing steel (PS) bars
    Sadoun, Oualid
    Merdas, Abdelghani
    Douadi, Abdellah
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2020, 34 (19) : 2120 - 2143
  • [40] Interaction forces in RC beams strengthened with near-surface mounted rectangular bars and strips
    Zhang, S. S.
    Teng, J. G.
    COMPOSITES PART B-ENGINEERING, 2013, 45 (01) : 697 - 709