Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:528 / 536
页数:9
相关论文
共 24 条
  • [11] A criterion for thermally-induced failure of electrical cable
    Fisher, Ryan P.
    Stoliarov, Stanislav I.
    Keller, Michael R.
    [J]. FIRE SAFETY JOURNAL, 2015, 72 : 33 - 39
  • [12] Grayson S., 2000, EIPEC2000 EC
  • [13] Hirschler M.M., 1992, Fire Mater, V16, P107, DOI DOI 10.1002/FAM.810160302
  • [15] Mangs J., 1997, FULL SCALE FIRE EXPT, P324
  • [16] Marlair G, 2002, P 7 INT S FIR SAF SC, P629, DOI [10.3801/iafss.fss.7-629, DOI 10.3801/IAFSS.FSS.7-629]
  • [17] Study on Pyrolysis Characteristics of Cross-linked Polyethylene Material Cable
    Mo Shan-jun
    Zhang Jun
    Liang Dong
    Chen Hong-yin
    [J]. 2012 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING, 2013, 52 : 588 - 592
  • [18] Experimental characterisation of ITER electric cables in postulated fire scenarios
    Passalacqua, Roberto
    Cortes, Pierre
    Taylor, Neill
    Beltran, David
    Zavaleta, Pascal
    Charbaut, Stephane
    [J]. FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 2650 - 2654
  • [19] MEASUREMENT OF MATERIAL FLAME SPREAD PROPERTIES
    QUINTIERE, J
    HARKLEROAD, M
    WALTON, D
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 1983, 32 (1-4) : 67 - 89