Smart electrode array device with CMOS multi-chip architecture for neural interface

被引:15
作者
Noda, T. [1 ]
Sasagawa, K. [1 ]
Tokuda, T. [1 ]
Terasawa, Y.
Tashiro, H. [2 ]
Kanda, H. [3 ]
Fujikado, T. [3 ]
Ohta, J. [1 ]
机构
[1] Nara Inst Sci & Technol, Ikoma, Nasa 6300192, Japan
[2] Kyushu Univ, Fukuoka 812, Japan
[3] Osaka Univ, Suita, Osaka 565, Japan
关键词
SUPRACHOROIDAL-TRANSRETINAL STIMULATION; VISION;
D O I
10.1049/el.2012.2784
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A CMOS integrated flexible neural interface device has been designed and fabricated. The device enables electrical stimulation of neural tissues using an array of smart electrodes. The smart electrodes have versatile functions owing to the use of a dedicated CMOS microchip. These multiple smart electrodes also provide the array with sophisticated functions with only four wiring connections to external equipment. Moreover, the multi-chip architecture of the device is highly flexible and has low invasiveness to living body tissue. An in vivo evaluation of retinal stimulation was performed after implanting the device in the eye of an experimental animal. The stimulus function of the device was successfully demonstrated by observing responses in the visual cortex caused by the stimulation.
引用
收藏
页码:1328 / 1329
页数:2
相关论文
共 8 条
  • [1] A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY
    CAMPBELL, PK
    JONES, KE
    HUBER, RJ
    HORCH, KW
    NORMANN, RA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) : 758 - 768
  • [2] Chao ZC, 2010, FRONT NEUROENG, V3
  • [3] Evaluation of phosphenes elicited by extraocular stimulation in normals and by suprachoroidal-transretinal stimulation in patients with retinitis pigmentosa
    Fujikado, Takashi
    Morimoto, Takeshi
    Kanda, Hiroyuki
    Kusaka, Shunji
    Nakauchi, Kazuaki
    Ozawa, Motoki
    Matsushita, Kenji
    Sakaguchi, Hirokazu
    Ikuno, Yasushi
    Kamei, Motohiro
    Tano, Yasuo
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (10) : 1411 - 1419
  • [4] Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats
    Kanda, H
    Morimoto, T
    Fujikado, T
    Tano, Y
    Fukuda, Y
    Sawai, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (02) : 560 - 566
  • [5] Proposal of application of pulsed vision chip for retinal prosthesis
    Ohta, J
    Yoshida, N
    Kagawa, K
    Nunoshita, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2002, 41 (4B): : 2322 - 2325
  • [6] A MEMS-based flexible multichannel ECoG-electrode array
    Rubehn, Birthe
    Bosman, Conrado
    Ostenveld, Robert
    Fries, Pascal
    Stieglitz, Thomas
    [J]. JOURNAL OF NEURAL ENGINEERING, 2009, 6 (03)
  • [7] CMOS-Based Multichip Networked Flexible Retinal Stimulator Designed for Image-Based Retinal Prosthesis
    Tokuda, Takashi
    Hiyama, Kohei
    Sawamura, Shigeki
    Sasagawa, Kiyotaka
    Terasawa, Yasuo
    Nishida, Kentaro
    Kitaguchi, Yoshiyuki
    Fujikado, Takashi
    Tano, Yasuo
    Ohta, Jun
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2009, 56 (11) : 2577 - 2585
  • [8] MICROFABRICATION TECHNIQUES FOR INTEGRATED SENSORS AND MICROSYSTEMS
    WISE, KD
    NAJAFI, K
    [J]. SCIENCE, 1991, 254 (5036) : 1335 - 1342