Revision Hip Arthroplasty with A Modular Cementless Stem: Mid-Term Follow Up

被引:30
作者
Jibodh, Stefan R. [1 ]
Schwarzkopf, Ran [2 ]
Anthony, Shawn G. [3 ]
Malchau, Henrik [3 ]
Dempsey, Kyle E. [2 ]
Estok, Daniel M., II [2 ]
机构
[1] Kaiser Permanente Walnut Creek, Dept Orthopaed Surg, Walnut Creek, CA USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Orthopaed Surg, Boston, MA 02115 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Orthopaed Surg,Harris Orthopaed Biomech & Bi, Boston, MA USA
关键词
revision hip arthroplasty; modular femoral stems; cementless femoral stems; fully coated femoral stems; EXTENDED TROCHANTERIC OSTEOTOMY; POROUS-COATED STEMS; PROXIMAL BONE LOSS; FEMORAL COMPONENT; UNITED-STATES; RADIOGRAPHIC ANALYSIS; KNEE ARTHROPLASTY; FIXATION; REPLACEMENT; DISLOCATION;
D O I
10.1016/j.arth.2012.07.031
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite the increasing volume of revision total hip arthroplasty (THA) being performed in the United States, there are few studies reporting mid-term clinical and radiographic outcomes of modular fully porous-coated femoral stems. We retrospectively studied a consecutive series of patients who underwent revision THA with a modular extensively porous-coated femoral component at a single institution and by a single surgeon. The final study group included 54 hips (52 patients) followed for an average of 84months. Ten-year survival rates with revision for any reason and revision for femoral loosening as endpoints were 94% and 100%, respectively. No complications regarding the modular junction were encountered. Of the 50 hips with adequate radiographs, all showed proximal ingrowth and 42 (84%) had both proximal and distal ingrowth. The modular, fully porous-coated femoral stem studied demonstrated excellent survivorship and bone ingrowth at mid-term follow up. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1167 / 1172
页数:6
相关论文
共 50 条
[41]   Intraoperative Complications and Mid-Term Follow-Up of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty and Hip Resurfacing Arthroplasty [J].
Miettinen, S. S. A. ;
Makinen, T. J. ;
Makela, K. ;
Huhtala, H. ;
Kettunen, J. S. ;
Remes, V. .
SCANDINAVIAN JOURNAL OF SURGERY, 2018, 107 (02) :180-186
[42]   Modular Femoral Stems for Revision Total Hip Arthroplasty [J].
Restrepo, Camilo ;
Mashadi, Magdalena ;
Parvizi, Javad ;
Austin, Matthew S. ;
Hozack, William J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :476-482
[43]   Mid-term results of titanium-titanium modular neck femoral stem in primary total hip arthroplasty [J].
Han, Kye Young ;
Jang, Jinwon ;
Kim, Keong-Hwan .
BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
[44]   Mid-term and long-term results of restoring rotation center in revision hip arthroplasty [J].
Heng Zhang ;
Jiansheng Zhou ;
Yang Liu ;
Jianzhong Guan ;
Hai Ding ;
Zhiyan Wang ;
Qirong Dong .
Journal of Orthopaedic Surgery and Research, 15
[45]   Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up [J].
Kang, Joon Soon ;
Na, Yeop ;
Ko, Bong Seong ;
Jeon, Yoon Sang .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03)
[46]   Mid-Term Outcomes and Complications with Cementless Distal Locking Hip Revision Stem with Hydroxyapatite Coating for Proximal Bone Defects and Fractures [J].
Carrera, Lluis ;
Haddad, Sleiman ;
Minguell, Joan ;
Amat, Carles ;
Corona, Pablo S. .
JOURNAL OF ARTHROPLASTY, 2015, 30 (06) :1035-1040
[47]   Outcomes of dual modular cementless femoral stems in revision hip arthroplasty [J].
Ghoz, Ali ;
Broadhead, Matthew L. ;
Morley, John ;
Tavares, Shawn ;
McDonald, David .
ORTHOPEDIC REVIEWS, 2014, 6 (01) :43-47
[48]   Outcomes of total hip arthroplasty with a standard prosthesis for the affected hip in patients with poliomyelitis sequelae: a mid-term retrospective follow-up study [J].
Shi, Lihan ;
Che, Guangwei ;
Huang, Yong ;
Yi, Min ;
Kang, Pengde .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
[49]   Total hip arthroplasty in developmental hip dysplasia using cementless tapered stem. Results after a minimum 10-year follow-up [J].
Faldini, Cesare ;
Nanni, Matteo ;
Leonetti, Danilo ;
Miscione, Maria Teresa ;
Acri, Francesco ;
Giannini, Sandro .
HIP INTERNATIONAL, 2011, 21 (04) :415-420
[50]   Mid-Term Outcomes of Dual Mobility Acetabular Cups for Revision Total Hip Arthroplasty [J].
Harwin, Steven F. ;
Sultan, Assem A. ;
Khlopas, Anton ;
Chughtai, Morad ;
Sodhi, Nipun ;
Piuzzi, Nicolas S. ;
Mont, Michael A. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (05) :1494-1500