Facile and controllable preparation of glucose biosensor based on Prussian blue nanoparticles hybrid composites

被引:31
|
作者
Li, Lei [1 ]
Sheng, Qinglin [1 ]
Zheng, Jianbin [1 ]
Zhang, Hongfang [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Shaanxi Prov Key Lab Elect Chem, Xian 710069, Shaanxi, Peoples R China
基金
美国国家科学基金会;
关键词
Prussian blue; Polyaniline; Carbon nanotubes; Hybrid composites; Biosensor;
D O I
10.1016/j.bioelechem.2008.07.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A glucose biosensor based on polyvinylpyrrolidone (PVP) protected Prussian blue nanoparticles (PBNPs)-polyaniline/multi-walled carbon nanotubes hybrid composites was fabricated by electrochemical method. A novel route for PBNPs preparation was applied in the fabrication with the help of PVP. and from scanning electron microscope images. Prussian blue particles on the electrode were found nanoscaled. The biosensor exhibits fast current response (< 6 s) and a linearity in the range from 6.7 x 10(-6) to 1.9 X 10(-3) M with a high sensitivity of 6.28 mu A mM(-1) and a detection limit of 6 x 10(-7) M (S/N = 3) for the detection of glucose. The apparent activation energy of enzyme-catalyzed reaction and the apparent Michaelis-Menten constant are 23.9 kJ mol(-1) and 1.9 mM respectively, which suggests a high affinity of the enzyme-substrate. This easy and controllable construction method of glucose biosensor combines the characteristics of the components of the hybrid composites, which favors the fast and sensitive detection of glucose with improved analytical capabilities. In addition, the biosensor was examined in human serum samples for glucose determination with a recovery between 95.0 and 104.5%. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
  • [41] Development of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays
    Zhi-Da Gao
    Yongfang Qu
    Tongtong Li
    Nabeen K. Shrestha
    Yan-Yan Song
    Scientific Reports, 4
  • [42] Application of Prussian blue based composite film with functionalized organic polymer to construction of enzymatic glucose biosensor
    Derwinska, K
    Miecznikowski, K
    Koncki, R
    Kulesza, PJ
    Glab, S
    Malik, MA
    ELECTROANALYSIS, 2003, 15 (23-24) : 1843 - 1849
  • [43] Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode
    Deng, Q
    Li, B
    Dong, SJ
    ANALYST, 1998, 123 (10) : 1995 - 1999
  • [44] A feasible electrochemical biosensor for determination of glucose based on Prussian blue - Enzyme aggregates cascade catalytic system
    Yan, Long
    Miao, Kunpeng
    Ma, Pengcheng
    Ma, Xiaoyan
    Bi, Ran
    Chen, Fang
    BIOELECTROCHEMISTRY, 2021, 141
  • [45] Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Zhang, Yannan
    Jin, Wanqin
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7490 - 7494
  • [46] An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ANALYTICAL BIOCHEMISTRY, 2004, 324 (01) : 115 - 122
  • [47] Development of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays
    Gao, Zhi-Da
    Qu, Yongfang
    Li, Tongtong
    Shrestha, Nabeen K.
    Song, Yan-Yan
    SCIENTIFIC REPORTS, 2014, 4
  • [48] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)
  • [49] Prussian blue nanoparticles doped nanocage for controllable immobilization and selective biosensing of enzyme
    Wu, Shuo
    Liu, Yiying
    Wu, He
    Ju, Huangxian
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (03) : 397 - 401
  • [50] Green synthesis of size controllable Prussian blue nanoparticles stabilized by soluble starch
    Zhang, Qian
    Zhang, Ling
    Li, Jinghong
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2007, 7 (12) : 4557 - 4561