Is Resternotomy a Risk for Continuous-Flow Left Ventricular Assist Device Outcomes?

被引:9
|
作者
Tsiouris, Athanasios [1 ]
Brewer, Robert J. [1 ]
Borgi, Jamil [1 ]
Hodari, Arielle [1 ]
Nemeh, Hassan W. [1 ]
Cogan, Chad M. [1 ]
Paone, Gaetano [1 ]
Morgan, Jeffrey A. [1 ]
机构
[1] Henry Ford Hosp, Inst Heart & Vasc, Div Cardiothorac Surg, Dept Gen Surg, Detroit, MI 48202 USA
关键词
left ventricular assist device (LVAD); reoperative sternotomy; outcomes; CARDIAC-SURGERY; STERNAL REENTRY; SCREENING SCALE; STILL; REOPERATION;
D O I
10.1111/jocs.12048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The number of patients undergoing resternotomy continues to rise. Although catastrophic hemorrhage remains a dreaded complication, most published data suggest that sternal reentrance is safe, with negligible postoperative morbidity and mortality. A significant proportion of left ventricular assist device (LVAD) implantations are reoperative cardiac procedures. The aim of our study was to compare outcomes between first time sternotomy and resternotomy patients receiving continuous-flow LVADs, as a bridge to transplantation or destination therapy. Methods and materials: From March 2006 through February 2012, 100 patients underwent implantation of a HeartMate II or HeartWare LVAD at our institution. Patients were stratified into two groups, primary sternotomy and resternotomy. Variables were compared using two-sided t-tests, chi-square tests, Cox proportional hazards models, and log-rank tests to determine whether there was a difference between the two groups and if resternotomy was a significant independent predictor of outcome. Results: We identified 29 patients (29%) who had resternotomy and 71 patients (71%) who had first time sternotomy. The resternotomy group was significantly older (56 years vs. 51 years, p?=?0.05), was more likely to have ischemic cardiomyopathy (ICM) (69% vs. 30%, p?<?0.001), chronic obstructive pulmonary disease (COPD) (31% vs. 14%, p?=?0.05) and had longer cardiopulmonary bypass times (135?min vs. 100?min, p?=?0.011). Survival rates at 30 days (93.1% vs. 95.8%, p?=?0.564), 180 days (82.8% vs. 93%, p?=?0.131), and 360 days (82.8% vs. 88.7%, p?=?0.398) were similar for the resternotomy and primary sternotomy groups, respectively. Postoperative complications were also comparable, except for re-exploration for bleeding which was higher for the resternotomy group (17.2% vs. 4.2%, p?=?0.029), although blood transfusion requirements were not significantly different (1.4 units vs. 1.2 units, p?=?0.815). Left and right heart catheterization measurements and echocardiographic (ECHO) findings after 1 and 6 months of LVAD therapy were similar between the two groups. Conclusions: Survival at 30, 180, and 360 days after LVAD implantation is similar between the resternotomy and primary sternotomy group. No major differences in complications or hemodynamic measurements were observed. Although a limited observational study, our findings agree with previously published resternotomy outcomes.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 50 条
  • [1] Evaluation of Risk Indices in Continuous-Flow Left Ventricular Assist Device Patients
    Schaffer, Justin M.
    Allen, Jeremiah G.
    Weiss, Eric S.
    Patel, Nishant D.
    Russell, Stuart D.
    Shah, Ashish S.
    Conte, John V.
    ANNALS OF THORACIC SURGERY, 2009, 88 (06) : 1889 - 1896
  • [2] Surgical approach to continuous-flow left ventricular assist device explantation: A comparison of outcomes
    Baldwin, Andrew C. W.
    Sandoval, Elena
    Letsou, George V.
    Mallidi, Hari R.
    Cohn, William E.
    Frazier, O. H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (01) : 192 - 198
  • [3] Impact of age on outcomes following continuous-flow left ventricular assist device implantation
    Lushaj, Entela B.
    Badami, Abbasali
    Osaki, Satoru
    Murray, Margaret
    Leverson, Glen
    Lozonschi, Lucian
    Akhter, Shahab
    Kohmoto, Takushi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (06) : 743 - 748
  • [4] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Cho, Sung-Min
    Moazami, Nader
    Katz, Stuart
    Bhimraj, Adarsh
    Shrestha, Nabin K.
    Frontera, Jennifer A.
    NEUROCRITICAL CARE, 2019, 31 (01) : 72 - 80
  • [5] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Sung-Min Cho
    Nader Moazami
    Stuart Katz
    Adarsh Bhimraj
    Nabin K. Shrestha
    Jennifer A. Frontera
    Neurocritical Care, 2019, 31 : 72 - 80
  • [6] Continuous-Flow Left Ventricular Assist Device Thrombosis: A Solvable Problem
    Pagani, Francis D.
    ASAIO JOURNAL, 2016, 62 (01) : 3 - 5
  • [7] Gastrointestinal bleeding on continuous-flow left ventricular assist device therapy
    Hammer, Yoav
    Bitar, Abbas
    Aaronson, Keith D.
    ESC HEART FAILURE, 2023, 10 (04): : 2214 - 2224
  • [8] Continuous-flow left ventricular assist device systems infections: current outcomes and management strategies
    Aburjania, Nana
    Hay, Christine M.
    Sohail, Muhammad R.
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (02) : 233 - 239
  • [9] Impact of continuous-flow left ventricular assist device support on right ventricular function
    Morgan, Jeffrey A.
    Paone, Gaetano
    Nemeh, Hassan W.
    Murthy, Raghav
    Williams, Celeste T.
    Lanfear, David E.
    Tita, Cristina
    Brewer, Robert J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04) : 398 - 403
  • [10] Effect of obesity on outcomes in patients who undergo implantation of a continuous-flow left ventricular assist device
    Nastasya Volkovicher
    Chitaru Kurihara
    Andre C. Critsinelis
    Masashi Kawabori
    Tadahisa Sugiura
    Marcos A. Manon
    Andrew B. Civitello
    Jeffrey A. Morgan
    Journal of Artificial Organs, 2018, 21 : 397 - 397