Multisensor System for Isotemporal Measurements to Assess Indoor Climatic Conditions in Poultry Farms

被引:19
作者
Bustamante, Eliseo [1 ,2 ]
Guijarro, Enrique [3 ]
Garcia-Diego, Fernando-Juan [4 ,5 ]
Balasch, Sebastian [6 ]
Hospitaler, Antonio [2 ]
Torres, Antonio G. [1 ]
机构
[1] Univ Politecn Valencia, Inst Anim Sci & Technol, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Politecn Valencia, Dept Construct Engn & Civil Engn Projects, Valencia 46022, Spain
[3] Univ Politecn Valencia, Dept Elect Engn, Valencia 46022, Spain
[4] Univ Politecn Valencia, Dept Appl Phys, Valencia 46022, Spain
[5] Univ Politecn Valencia, Ctr Phys Technol, Asociated Unity ICMM CSIC UPV, Valencia 46022, Spain
[6] Univ Politecn Valencia, Dept Stat Operat Res & Qual, Valencia 46022, Spain
关键词
poultry building; sensors; air velocity; isotemporal measurements; multipoint measurements; troubleshooting; COMPUTATIONAL FLUID-DYNAMICS; INSTRUMENTATION SYSTEM; FOOD-INDUSTRY; AIR VELOCITY; HOT WIRES; VENTILATION; TEMPERATURE; BROILER; TURBULENCE; BUILDINGS;
D O I
10.3390/s120505752
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rearing of poultry for meat production (broilers) is an agricultural food industry with high relevance to the economy and development of some countries. Periodic episodes of extreme climatic conditions during the summer season can cause high mortality among birds, resulting in economic losses. In this context, ventilation systems within poultry houses play a critical role to ensure appropriate indoor climatic conditions. The objective of this study was to develop a multisensor system to evaluate the design of the ventilation system in broiler houses. A measurement system equipped with three types of sensors: air velocity, temperature and differential pressure was designed and built. The system consisted in a laptop, a data acquisition card, a multiplexor module and a set of 24 air temperature, 24 air velocity and two differential pressure sensors. The system was able to acquire up to a maximum of 128 signals simultaneously at 5 second intervals. The multisensor system was calibrated under laboratory conditions and it was then tested in field tests. Field tests were conducted in a commercial broiler farm under four different pressure and ventilation scenarios in two sections within the building. The calibration curves obtained under laboratory conditions showed similar regression coefficients among temperature, air velocity and pressure sensors and a high goodness fit (R-2 = 0.99) with the reference. Under field test conditions, the multisensor system showed a high number of input signals from different locations with minimum internal delay in acquiring signals. The variation among air velocity sensors was not significant. The developed multisensor system was able to integrate calibrated sensors of temperature, air velocity and differential pressure and operated succesfully under different conditions in a mechanically-ventilated broiler farm. This system can be used to obtain quasi-instantaneous fields of the air velocity and temperature, as well as differential pressure maps to assess the design and functioning of ventilation system and as a verification and validation (V&V) system of Computational Fluid Dynamics (CFD) simulations in poultry farms.
引用
收藏
页码:5752 / 5774
页数:23
相关论文
共 43 条
[1]  
[Anonymous], [No title captured]
[2]  
[Anonymous], MATL CENTR
[3]  
ASAE, 1986, ASABE STAND 2009, P1
[4]   Analysis of airflow through experimental rural buildings: Sensitivity to turbulence models [J].
Bartzanas, T. ;
Kittas, C. ;
Sapounas, A. A. ;
Nikita-Martzopoulou, Ch. .
BIOSYSTEMS ENGINEERING, 2007, 97 (02) :229-239
[5]  
Benedict R.P., 1984, FUNDAMENTALS TEMPERA, V3rd
[6]  
Berckmans D., 1991, INDOOR AIR, V1, P323, DOI [DOI 10.1111/J.1600-0668.1991.09-13.X, 10.1111/j.1600-0668.1991.09-13, DOI 10.1111/J.1600-0668.1991.09-13]
[7]   Application of computational fluid dynamics to the prediction of airflow in a mechanically ventilated commercial poultry building [J].
Blanes-Vidal, V. ;
Guijarro, E. ;
Balasch, S. ;
Torres, A. G. .
BIOSYSTEMS ENGINEERING, 2008, 100 (01) :105-116
[8]   Development and field test of an on-line computerized instrumentation system for air velocity, temperature and differential pressure measurements in poultry houses [J].
Blanes-Vidal, V. ;
Guijarro, E. ;
Nadimi, E. S. ;
Torres, A. G. .
SPANISH JOURNAL OF AGRICULTURAL RESEARCH, 2010, 8 (03) :570-579
[9]   AIR MIXING FANS IN A BROILER BUILDING - THEIR USE AND EFFICIENCY [J].
BOON, CR ;
BATTAMS, VA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1988, 39 (02) :137-147
[10]   Ventilation rates in mechanically-ventilated commercial poultry buildings in Southern Europe: Measurement system development and uncertainty analysis [J].
Calvet, S. ;
Cambra-Lopez, M. ;
Blanes-Vidal, V. ;
Estelles, F. ;
Torres, A. G. .
BIOSYSTEMS ENGINEERING, 2010, 106 (04) :423-432