The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications

被引:34
|
作者
Guenther, Benedikt [1 ,2 ]
Gradl, Regine [1 ,2 ]
Jud, Christoph [1 ,2 ]
Eggl, Elena [1 ,2 ]
Huang, Juanjuan [1 ,2 ]
Kulpe, Stephanie [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Dierolf, Martin [1 ,2 ]
Pfeiffer, Franz [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, Dept Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch Bioengn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-85748 Munich, Germany
关键词
Munich Compact Light Source; inverse Compton X-ray sources; X-ray phase-contrast imaging and tomography; X-ray absorption spectroscopy; micro-beam radiation therapy; SYNCHROTRON-RADIATION; ABSORPTION SPECTROSCOPY; COMPTON-SCATTERING; PHASE-RETRIEVAL; LASER-LIGHT; BEAMS; STABILIZATION; MAMMOGRAPHY; ANGIOGRAPHY; TOMOGRAPHY;
D O I
10.1107/S1600577520008309
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Inverse Compton scattering provides means to generate low-divergence partially coherent quasi-monochromatic, i.e. synchrotron-like, X-ray radiation on a laboratory scale. This enables the transfer of synchrotron techniques into university or industrial environments. Here, the Munich Compact Light Source is presented, which is such a compact synchrotron radiation facility based on an inverse Compton X-ray source (ICS). The recent improvements of the ICS are reported first and then the various experimental techniques which are most suited to the ICS installed at the Technical University of Munich are reviewed. For the latter, a multipurpose X-ray application beamline with two end-stations was designed. The beamline's design and geometry are presented in detail including the different set-ups as well as the available detector options. Application examples of the classes of experiments that can be performed are summarized afterwards. Among them are dynamic in vivo respiratory imaging, propagation-based phase-contrast imaging, grating-based phase-contrast imaging, X-ray microtomography, K-edge subtraction imaging and X-ray spectroscopy. Finally, plans to upgrade the beamline in order to enhance its capabilities are discussed.
引用
收藏
页码:1395 / 1414
页数:20
相关论文
共 50 条
  • [1] Advanced X-ray imaging at beamline 07 of the SAGA Light Source
    Yoneyama, Akio
    Takeya, Satoshi
    Lwin, Thet Thet
    Takamatsu, Daiko
    Baba, Rika
    Konishi, Kumiko
    Fujita, Ryusei
    Kobayashi, Keisuke
    Shima, Akio
    Kawamoto, Masahide
    Setoyama, Hiroyuki
    Ishiji, Kotaro
    Seno, Yoshiki
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1966 - 1977
  • [2] Design of the Soft X-ray Tomography Beamline at Taiwan Photon Source
    Su, Yi-Jr
    Fu, Huang-Wen
    Chung, Shih-Chun
    Fung, Hok-Sum
    Liu, Din-Goa
    Huang, Liang-Jen
    Yan, Hong-Yi
    Chou, Yu-Ching
    Yin, Gung-Chian
    Lai, Lee-Jene
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [3] BL-02: a versatile X-ray scattering and diffraction beamline for engineering applications at Indus-2 synchrotron source
    Gupta, Pooja
    Rao, P. N.
    Swami, M. K.
    Bhakar, A.
    Lal, Sohan
    Garg, S. R.
    Garg, C. K.
    Gauttam, P. K.
    Kane, S. R.
    Raghuwanshi, V. K.
    Rai, S. K.
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1193 - 1201
  • [4] Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography
    Torikoshi, M
    Tsunoo, T
    Endo, M
    Noda, K
    Kumada, M
    Yamada, S
    Soga, F
    Hyodo, K
    JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (03) : 371 - 377
  • [5] Optical design of micro-focus X-ray photon correlation spectroscopy beamline at Shenzhen Light Source
    Lei, Tao
    Tan, Yonggen
    Zhang, Zheng
    Chen, Siyuan
    Feng, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [6] A new soft x-ray photoemission microscopy beamline at the National Synchrotron Light Source
    Flege, J. I.
    Vescovo, E.
    Nintzel, G.
    Lewis, L. H.
    Hulbert, S.
    Sutter, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) : 855 - 858
  • [7] The compact X-ray source ThomX
    Favier, P.
    Amoudry, L.
    Cassou, K.
    Dupraz, K.
    Martens, A.
    Monard, H.
    Zomer, F.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VI, 2017, 10387
  • [8] Infrared and X-ray simultaneous spectroscopy: a novel conceptual beamline design for time resolved experiments
    Marcelli, Augusto
    Xu, Wei
    Hampai, Dariush
    Malfatti, Luca
    Innocenzi, Plinio
    Schade, Ulrich
    Wu, Ziyu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) : 2095 - 2108
  • [9] BoCXS: A compact multidisciplinary X-ray source
    Bazzani, A.
    Cardarelli, P.
    Paterno, G.
    Placidi, M.
    Taibi, A.
    Turchetti, G.
    PHYSICS OPEN, 2020, 5
  • [10] Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source
    Reininger, R.
    Keavney, D. J.
    Borland, M.
    Young, L.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 654 - 659