Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

被引:0
作者
Yavas, G. [1 ]
Yavas, C. [2 ]
Acar, H. [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Radiat Oncol, Konya, Turkey
[2] Konya Training & Res Hosp, Dept Radiat Oncol, Konya, Turkey
来源
IRANIAN JOURNAL OF RADIATION RESEARCH | 2012年 / 10卷 / 3-4期
关键词
Breast cancer; conformal radiotherapy; dose volume histograms; field-in-field technique; INTENSITY-MODULATED RADIOTHERAPY; CONTRALATERAL BREAST; BOOST; CARCINOMAS; THERAPY; TRIALS; IMRT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were created for the entire breast. FIF plans and CRT plans were compared for doses in the planning target volume (PTV), the organ at risk (OAR) volume including ipsilateral lung, heart, left ascending coronary artery (LAD) and the contralateral breast, the homogeneity index (HI), and the monitor unit (MU) counts required for the treatment. Paired samples t-test was used for statistical analysis. Results: The FIF technique significantly reduced the maximum dose of the PTV as well as the mean doses of the heart, LAD, ipsilateral lung and the contralateral breast (p values were <0.001 for each). When the OAR volumes irradiated with 2, 5, 10, 20, 30 and 40 Gy were compared, the results were in favor of the FT technique. The volume receiving <20 Gy of the prescription dose for the ipsilateral lung was significantly decreased using FIF technique (p<0.001). FIF technique allowed us more homogenous dose distribution with lower MUs. Conclusion: The FIF technique provided better dose distribution in the PTV and significantly reduced the doses in the OAR. Considering the lower MUs required for treatment the FIF technique seems to be more advantageous than CRT during whole breast irradiation. Iran. J. Radiat. Res., 2012; 10(3-4): 131-138
引用
收藏
页码:131 / 138
页数:8
相关论文
共 27 条
  • [21] Role of a 10-Gy boost in the conservative treatment of early breast cancer: Results of a randomized clinical trial in Lyon, France
    Romestaing, P
    Lehingue, Y
    Carrie, C
    Coquard, R
    Montbarbon, X
    Ardiet, JM
    Mamelle, N
    Gerard, JP
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (03) : 963 - 968
  • [22] Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer
    Sasaoka, Masahiro
    Futami, Tomoyuki
    [J]. INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2011, 16 (03) : 250 - 256
  • [23] Stasi M, 1997, Radiol Med, V93, P596
  • [24] Storey MR, 2001, CANCER J, V7, P492
  • [25] Warlick W B, 1997, Med Dosim, V22, P185, DOI 10.1016/S0958-3947(97)00015-0
  • [26] Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas. I: Dosimetric results
    Wu, QW
    Mohan, R
    Morris, M
    Lauve, A
    Schmidt-Ullrich, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 573 - 585
  • [27] Optimized MLC-beam arrangements for tangential breast irradiation
    Zackrisson, B
    Arevärn, M
    Karlsson, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 54 (03) : 209 - 212