A Novel, Fully Covered Laser-Cut Nitinol Stent with Antimigration Properties for Nonresectable Distal Malignant Biliary Obstruction: A Multicenter Feasibility Study

被引:35
作者
Lsayama, Hiroyuki [1 ]
Kawakubo, Kazumichi [1 ]
Nakai, Yousuke [1 ]
Inoue, Kouta [2 ]
Gon, Chimyon [2 ]
Matsubara, Saburo [3 ]
Kogure, Hirofumi [1 ]
Ito, Yukiko [4 ]
Tsujino, Takeshi [4 ]
Mizuno, Suguru [5 ]
Hamada, Tsuyoshi [1 ]
Uchino, Rie [1 ]
Miyabayashi, Koji [1 ]
Yamamoto, Keisuke [1 ]
Sasaki, Takashi [1 ]
Yamamoto, Natsuyo [1 ]
Hirano, Kenji [1 ]
Sasahira, Naoki [1 ]
Tada, Minoru [1 ]
Koike, Kazuhiko [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo 1138655, Japan
[2] ZEON Med Inc, Ctr Res & Dev, Kawasaki, Kanagawa, Japan
[3] Tokyo Police Hosp, Dept Gastroenterol, Tokyo, Japan
[4] Japanese Red Cross Med Ctr, Dept Gastroenterol, Tokyo, Japan
[5] Kanto Cent Hosp, Dept Gastroenterol, Tokyo, Japan
关键词
Cholestasis; extrahepatic; Stents; Cholangiography; Endoscopic retrograde; EXPANDABLE METAL STENTS; SAFETY; CHOLECYSTITIS; PANCREATITIS; PALLIATION; MANAGEMENT; EFFICACY;
D O I
10.5009/gnl.2013.7.6.725
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Stent migration occurs frequently, but the prevention of complications resulting from covered self-expandable metal stents (C-SEMSs) remains unresolved. We prospectively assessed a newly developed C-SEMS, a modified covered Zeo stent (m-CZS), in terms of its antimigration effect. Methods: Between February 2010 and January 2011, an m-CZS was inserted into 42 patients (31 initial drainage cases and 11 reintervention cases) at a tertiary referral center and three affiliated hospitals. The laser-cut stent was flared for 1.5 cm at both ends, with a 1 cm raised bank located 1 cm in from each flared end. The main outcome of this study was the rate of stent migration, and secondary outcomes were the rate of recurrent biliary obstruction (RBO), the time to RBO, the frequencies of complications, and overall survival. Results: Of the 31 patients with initial drainage, stent migration occurred in four (12.9%, 95% confidence interval, 5.1% to 29.0%), with a mean time of 131 days. RBO occurred in 18 (58%), with a median time to RBO of 107 days. Following previous C-SEMS migration, seven of 10 patients (70%) did not experience m-CZS migration until death. Conclusions: m-CZSs with antimigration properties effectively, although not completely, prevented stent migration after stent insertion.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 19 条
[1]   Polyurethane-covered metal stent for management of distal malignant biliary obstruction [J].
Isayama, H ;
Komatsu, Y ;
Tsujino, T ;
Yoshida, H ;
Tada, M ;
Shiratori, Y ;
Kawabe, T ;
Omata, M .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (03) :366-370
[2]   A prospective randomised study of "covered'' versus "uncovered'' diamond stents for the management of distal malignant biliary obstruction [J].
Isayama, H ;
Komatsu, Y ;
Tsujino, T ;
Sasahira, N ;
Hirano, K ;
Toda, N ;
Nakai, Y ;
Yamamoto, N ;
Tada, M ;
Yoshida, H ;
Shiratori, Y ;
Kawabe, T ;
Omata, M .
GUT, 2004, 53 (05) :729-734
[3]  
Isayama H, 2012, GASTROINTEST ENDOSC, V75, P380
[4]   Covered biliary metal stent: which are worse-the concepts, current models, or insertion methods? [J].
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Togawa, Osamu ;
Kogure, Hirofumi ;
Koike, Kazuhiko .
GASTROINTESTINAL ENDOSCOPY, 2011, 73 (06) :1329-1330
[5]   Management of distal malignant biliary obstruction with the ComVi stent, a new covered metallic stent [J].
Isayama, Hiroyuki ;
Kawabe, Takao ;
Nakai, Yousuke ;
Ito, Yukiko ;
Togawa, Osamu ;
Kogure, Hirofumi ;
Yashima, Yoko ;
Yagioka, Hiroshi ;
Matsubara, Saburo ;
Sasaki, Takashi ;
Sasahira, Naoki ;
Hirano, Kenji ;
Tsujino, Takeshi ;
Tada, Minoru ;
Omata, Masao .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (01) :131-137
[6]   Measurement of radial and axial forces of biliary self-expandable metallic stents [J].
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Toyokawa, Yoshihide ;
Togawa, Osamu ;
Gon, Chimyon ;
Ito, Yukiko ;
Yashima, Yoko ;
Yagioka, Hiroshi ;
Kogure, Hirofumi ;
Sasaki, Takashi ;
Arizumi, Toshihiko ;
Matsubara, Saburo ;
Yamamoto, Natsuyo ;
Sasahira, Naoki ;
Hirano, Kenji ;
Tsujino, Takeshi ;
Toda, Nobuo ;
Tada, Minoru ;
Kawabe, Takao ;
Omata, Masao .
GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) :37-44
[7]   A multicenter analysis of safety and outcome of removal of a fully covered self-expandable metal stent during ERCP [J].
Kasher, John A. ;
Corasanti, James G. ;
Tarnasky, Paul R. ;
McHenry, Lee ;
Fogel, Evan ;
Cunningham, John .
GASTROINTESTINAL ENDOSCOPY, 2011, 73 (06) :1292-1297
[8]   Risk factors for pancreatitis following transpapillary self-expandable metal stent placement [J].
Kawakubo, Kazumichi ;
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Togawa, Osamu ;
Sasahira, Naoki ;
Kogure, Hirofumi ;
Sasaki, Takashi ;
Matsubara, Saburo ;
Yamamoto, Natsuyo ;
Hirano, Kenji ;
Tsujino, Takeshi ;
Toda, Nobuo ;
Tada, Minoru ;
Omata, Masao ;
Koike, Kazuhiko .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (03) :771-776
[9]   Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study [J].
Kullman, Eric ;
Frozanpor, Farshad ;
Soderlund, Claes ;
Linder, Stefan ;
Sandstrom, Per ;
Lindhoff-Larsson, Anna ;
Toth, Ervin ;
Lindell, Gert ;
Jonas, Eduard ;
Freedman, Jacob ;
Ljungman, Martin ;
Rudberg, Claes ;
Ohlin, Bo ;
Zacharias, Rebecka ;
Leijonmarck, Carl-Eric ;
Teder, Kalev ;
Ringman, Anders ;
Persson, Gunnar ;
Gozen, Mehmet ;
Eriksson, Olle .
GASTROINTESTINAL ENDOSCOPY, 2010, 72 (05) :915-923
[10]   Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration [J].
Moon, Sung-Hoon ;
Kim, Myung-Hwan ;
Park, Do Hyun ;
Song, Tae Joon ;
Eum, Junbum ;
Lee, Sang Soo ;
Seo, Dong Wan ;
Lee, Sung Koo .
GASTROINTESTINAL ENDOSCOPY, 2010, 72 (01) :86-91