Aortopulmonary Fistula After Transcatheter Pulmonary Valve Replacement

被引:11
作者
Kenny, Damien [1 ]
Holoshitz, Noa [1 ]
Turner, David [1 ]
Hijazi, Ziyad M. [1 ]
机构
[1] Rush Univ, Med Ctr, Rush Ctr Congenital & Struct Heart Dis, Chicago, IL 60612 USA
关键词
device closure; fistula; pulmonary valve; transcatheter; BALLOON ANGIOPLASTY;
D O I
10.1161/CIRCINTERVENTIONS.113.000654
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:E67 / E68
页数:2
相关论文
共 4 条
[1]   Melody Valve Erosion into the Ascending Aorta [J].
Taggart, Nathaniel W. ;
Hagler, Donald J. ;
Connolly, Heidi M. .
CONGENITAL HEART DISEASE, 2013, 8 (02) :E64-E64
[2]   Acute Heart Failure after Percutaneous Pulmonary Valve (Melody Valve) Implantation [J].
Taggart, Nathaniel W. ;
Connolly, Heidi M. ;
Hagler, Donald J. .
CONGENITAL HEART DISEASE, 2013, 8 (02) :E61-E63
[3]   Aortopulmonary window due to balloon angioplasty after arterial switch operation [J].
Takayama, H ;
Sekiguchi, A ;
Chikada, M ;
Noma, M ;
Ishida, R .
ANNALS OF THORACIC SURGERY, 2002, 73 (02) :659-661
[4]   Iatrogenic Aortopulmonary Fistula Occurring After Pulmonary Artery Balloon Angioplasty: A Word of Caution [J].
Vida, Vladimiro L. ;
Biffanti, Roberta ;
Stellin, Giovanni ;
Milanesi, Ornella .
PEDIATRIC CARDIOLOGY, 2013, 34 (05) :1267-1268