Corneal biomechanical measurements before and after laser in situ keratomileusis

被引:119
作者
Chen, Michael C.
Lee, Nancy [2 ]
Bourla, Nirit
Hamilton, D. Rex [1 ]
机构
[1] Univ Calif Los Angeles, Jules Stein Eye Inst, Cornea & External Dis Div, David Geffen Sch Med, Los Angeles, CA 90095 USA
[2] Temple Univ, Sch Med, Philadelphia, PA 19122 USA
关键词
D O I
10.1016/j.jcrs.2008.06.035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the correlation between corneal biomechanical properties and surgical parameters in myopic patients before and after laser in situ keratomileusis (LASIK). SETTING: UCLA Laser Refractive Center of the Jules Stein Eye Institute, Los Angeles, California, USA. METHODS: In 43 eyes of 43 patients, the Ocular Response Analyzer was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) before and 1 month after LASIK. Manifest refraction spherical equivalent (MRSE), preoperative central corneal thickness (CCT), flap thickness (FT), and ablation depth (AD) were also recorded. Changes in these parameters after LASIK were calculated and the correlations between the change in CH (Delta CH), change in CRF (Delta CRF) and the AD, change in MRSE (Delta MRSE), and CCT were examined. The relationship between Delta CRF and Delta MRSE was examined by linear regression analysis. RESULTS: The preoperative mean CH and mean CRF (11.52 mm Hg +/- 1.28 [SD] and 11.68 +/- 1.40 mm Hg, respectively) were significantly higher than postoperative values (9.48 +/- 1.24 mm Hg and 8.47 +/- 1.53 mm Hg, respectively) (P<.0001). A higher attempted correction was correlated with a larger Delta CH and Delta CRF (AD, r = 0.47 and r = 0.65, respectively; Delta MRSE, r = 0.51 and r = 0.66, respectively). No correlation was found between Delta CH, Delta CRF, and preoperative CCT. CONCLUSIONS: Changes in CH and CRF after LASIK suggest alteration in corneal biomechanics correlating with attempted correction. The CRF parameter may be more useful than the CH parameter in assessing biomechanical changes resulting from LASIK.
引用
收藏
页码:1886 / 1891
页数:6
相关论文
共 30 条
[1]  
Ambrosio R, 2003, J REFRACT SURG, V19, P24
[2]   Retrospective comparison of 3 laser platforms to correct myopic spheres and spherocylinders using conventional and wavefront-guided treatments [J].
Binder, Perry S. ;
Rosenshein, Joseph .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1158-1176
[3]   Ectasia after laser in situ keratomileusis [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) :2419-2429
[4]   Progressive post-LASIK keratectasia - Biomechanical instability or chronic disease process? [J].
Comaish, IF ;
Lawless, MA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2206-2213
[5]   Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: Is there a difference between advanced surface ablation and sub-Bowman's keratomileusis? [J].
Dawson, Daniel G. ;
Grossniklaus, Hans E. ;
McCarey, Bernard E. ;
Edelhauser, Henry F. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (01) :90-96
[6]   Thin flap laser in situ keratomileusis:: Flap dimensions with the Moria LSK-One manual microkeratome using the 100-μm head [J].
Duffey, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (06) :1159-1162
[7]   Biomechanics and wound healing in the cornea [J].
Dupps, William J., Jr. ;
Wilson, Steven E. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (04) :709-720
[8]  
Gatinel D, 2007, J REFRACT SURG, V23, P76
[9]  
Guirao A, 2005, J REFRACT SURG, V21, P176
[10]   Five-year outcome of LASIK for myopia [J].
Kato, Naoko ;
Toda, Ikuko ;
Hori-Komai, Yoshiko ;
Sakai, Chikako ;
Tsubota, Kazuo .
OPHTHALMOLOGY, 2008, 115 (05) :839-844