Passive cooling concept for onboard heat sources in aircrafts

被引:21
作者
Tecchio, C. [1 ]
Paiva, K. V. [1 ]
Oliveira, J. L. G. [1 ]
Mantelli, M. B. H. [1 ]
Gandolfi, R. [2 ]
Ribeiro, L. G. S. [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Mech Engn, Lepten Labtucal, BR-88040900 Florianopolis, SC, Brazil
[2] Embraer SA, BR-12227901 Sao Jose Dos Campos, SP, Brazil
关键词
Aircraft; Cooling system; Heat exchanger system; Heat pipe; Thermosyphons; Couplings; 2-PHASE CLOSED THERMOSIPHON; EFFECTIVE PARAMETERS; LOOP THERMOSIPHON; PIPE; SYSTEM;
D O I
10.1016/j.expthermflusci.2016.11.038
中图分类号
O414.1 [热力学];
学科分类号
摘要
A passive cooling system based on heat pipe technology was tested in-flight in an Embraer test aircraft. Avionics thermal behavior was simulated by employing electrical resistances with input power ranging from 40 to 850 W. Heat is transported from the resistances to the evaporator of a recently patented heat exchanger system (HES) by intermediary heat transfer elements (IHTEs), consisting of one heat pipe and four thermosyphons. The HES consists of loop-thermosyphons with a shared evaporator connected to two parallel condensers, one at the fuselage and another within the air-conditioning system. The couplings between HES evaporator and IHTE condensers were designed to assure practical fitting and low contact resistance. Experiments were conducted with Mach numbers of 0.55 up to 0.78 at altitudes of 4.5, 9.1 and 10.6 km, corresponding to air static temperatures of 0, -30 and -43 degrees C, respectively. IHTEs and HES behaviors were also investigated during roller coaster and G-load turn maneuvers. Heat sink changes surrounding the HES condensers owing to different altitudes hardly affect IHTEs. Heat pipe and thermosyphons with 0.7 m length can dissipate 120 W and 500 W, respectively. Convection can be an alternative where heat conduction between avionics and IHTE evaporators is not possible. Two thermosyphons with evaporator fins dissipated 586 W with the air temperature within the convective system of about 80 degrees C. Aircraft maneuvers do not affect the thermal behavior of heat pipe technologies. Efficient thermal control of avionics is at hand. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:402 / 413
页数:12
相关论文
共 35 条
[1]   Double-Loop Thermosyphon for Electric Components Cooling [J].
Agostini, Francesco ;
Habert, Mathieu ;
Molitor, Francoise ;
Flueeckiger, Reto ;
Kaufmann, Lilian ;
Bergamini, Alessio ;
Rossi, Marco ;
Besana, Stefano .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2014, 4 (02) :223-231
[2]  
Cai Q., 2007, J SPACECRAFT ROCKETS, V44, P2
[3]   THE GEYSER EFFECT IN A 2-PHASE THERMOSYPHON [J].
CASAROSA, C ;
LATROFA, E ;
SHELGINSKI, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (06) :933-941
[4]   Heat pipe for cooling of electronic equipment [J].
Chang, Yu-Wei ;
Cheng, Chiao-Hung ;
Wang, Jung-Chang ;
Chen, Sih-Li .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (11) :3398-3404
[5]   Experimental investigations and modeling of a loop thermosyphon for cooling with zero electrical consumption [J].
Chehade, Ali ;
Louahlia-Gualous, Hasna ;
Le Masson, Stephane ;
Lepinasse, Eric .
APPLIED THERMAL ENGINEERING, 2015, 87 :559-573
[6]   Experimental investigation of effective parameters on geyser periodicity in a vertical heated system [J].
Chen, Jinbo ;
Yang, Shengxing ;
Liao, Shiliang ;
Cao, Xuewu .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 68 :163-176
[7]   Investigation on thermal design of a rack with the pulsating heat pipe for cooling CPUs [J].
Dang, Chao ;
Jia, Li ;
Lu, Qianyi .
APPLIED THERMAL ENGINEERING, 2017, 110 :390-398
[8]  
Faghri A., 2010, Advanced Heat and Mass Transfer
[9]  
Faghri Amir., 1995, HEAT PIPE SCI TECHNO
[10]  
Gandolfi R., 2015, SAE TECHNICAL PAPER