Thermal characteristics comparison for several roofs of naturally ventilated rooms

被引:0
|
作者
Zheng, Shu Kui [1 ]
Zhang, Jie [2 ]
机构
[1] Xihua Univ, Sch Architecture & Civil Engn, Chengdu 610039, Peoples R China
[2] Sichuan Vocat & Tech Coll Commun, Dept Econ Management, Chengdu 611130, Peoples R China
来源
PROGRESS IN CIVIL ENGINEERING, PTS 1-4 | 2012年 / 170-173卷
基金
中国国家自然科学基金;
关键词
roof construction; thermal characteristics; ventilated roof; green roof;
D O I
10.4028/www.scientific.net/AMM.170-173.2681
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Four kinds of insulation roofs of naturally ventilated rooms in Chengdu(P.R.C) were tested to evaluate the thermal performance in summer. The thermal characteristics of roofs with different construction were compared by regression analysis. The experimental results showed a strong negative correlation between the highest outdoor air temperature and the largest temperature increment. As the highest outdoor air over 29.1 degrees C, the light green ventilated roof has the best insulation performance. Under "sunny - rain" climatic conditions in summer, the heat flux through the extruded polystyrene insulation roof was always toward outside, which is not good for cooling the structural roof at night. The heat flux of inner surface of concrete slab ventilated roof was the most sensitive with mean solar radiation, and it has the worst performance for attenuating fluctuations of solar air temperature of outdoors.
引用
收藏
页码:2681 / +
页数:2
相关论文
共 50 条
  • [41] Methane Emission Characteristics of Naturally Ventilated Cattle Buildings
    Hempel, Sabrina
    Willink, Diliara
    Janke, David
    Ammon, Christian
    Amon, Barbara
    Amon, Thomas
    SUSTAINABILITY, 2020, 12 (10)
  • [42] Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    APPLIED THERMAL ENGINEERING, 2012, 40 : 1 - 7
  • [43] Prediction of indoor climate and thermal comfort for cooling in ventilated residence rooms
    Yao, Runming
    Chen, Qigao
    Li, Baizhan
    Peng, Xuya
    Feng, Ya
    Nuantong Kongtiao/HV & AC, 27 (06): : 5 - 9
  • [44] HEAT-TRANSFER IN NATURALLY VENTILATED ROOMS - DATA FROM FULL-SCALE MEASUREMENTS
    CHANDRA, S
    KERESTECIOGLU, AA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 55 - 55
  • [45] Thermal comfort assessment and characteristics of occupant's behaviour in naturally ventilated buildings in composite climate of India
    Kumar, Sanjay
    Singh, Manoj Kumar
    Loftness, Vivian
    Mathur, Jyotirmay
    Mathur, Sanjay
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2016, 33 : 108 - 121
  • [46] Effects of air and moisture flows on the thermal performance of insulations in ventilated roofs and walls
    CRIR-Isover St.-Gobain, Rantigny, France
    J Therm Insul Build Envelopes, (369-385):
  • [47] Experimental study of the thermal insulation performance of phase-change ventilated roofs
    Shi, Yu
    Zhao, Yunchao
    Zhang, Yanmei
    Jiang, Dahua
    Fan, Zhixuan
    ENERGY AND BUILDINGS, 2024, 303
  • [48] Occupant Perceptions of an Indoor Thermal Environment in a Naturally Ventilated Building
    Ilyas, Salman
    Emery, Ashley
    Heerwagen, Judith
    Heerwagen, Dean
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 114 - 121
  • [49] Thermal Comfort Studies in Naturally Ventilated Buildings in Jakarta, Indonesia
    Karyono, Tri Harso
    Sri, Elita
    Sulistiawan, Jevi Ganda
    Triswanti, Yenny
    BUILDINGS, 2015, 5 (03) : 917 - 932
  • [50] Coupled simulations for naturally ventilated rooms between building simulation (BS) and computational fluid dynamics (CFD) for better prediction of indoor thermal environment
    Wang, Liping
    Wong, Nyuk Hien
    BUILDING AND ENVIRONMENT, 2009, 44 (01) : 95 - 112