An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood

被引:43
作者
Jagerdeo, Eshwar [1 ]
Montgomery, Madeline A. [1 ]
LeBeau, Marc A. [1 ]
Sibum, Martin [2 ]
机构
[1] Fed Bur Invest Lab, Quantico, VA 22135 USA
[2] Spark Holland Inc, NL-7800 AJ Emmen, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 874卷 / 1-2期
关键词
SPE; LC/MS; Cocaine; Cocaine metabolites; Whole blood;
D O I
10.1016/j.jchromb.2008.08.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As laboratories are called upon to develop novel, fast, and sensitive methods, here we present a completely automated method for the analysis of cocaine and its metabolites (benzoylecgonine,ecgonine methyl ester, ecgonine and cocaethylene) from whole blood. This method utilizes an online solid-phase extraction (SPE) with high performance liquid chromatographic separation and tandem mass spectrometric detection. Pretreatment of samples involve only protein precipitation and ultracentrifugation. An efficient online solid-phase extraction (SPE) procedure was developed using Hysphere MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50 mm x 3.00 mm i.d., 5 mu m) column was used for the complete separation of all components. Analysis was by positive ion mode electrospray ionization tandem mass spectrometry, using multiple reaction monitoring (MRM) to enhance the selectivity and sensitivity of the method. For the analysis, two MRM transitions are monitored for each analyte and one transition is monitored for each internal standard. With a 30-mu L sample injection, linearity was analyte dependent but generally fell between 8 and 500 ng/mL The limits of detection (LODs) for the method ranged from 3 to 16 ng/mL and the limits of quantitation (LOQs) ranged from 8 to 47 ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and %precision as <9% for all components at each QC level. Published by Elsevier B.V.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 27 条
[1]   DETERMINATION OF COCAINE AND BENZOYLECGONINE BY DERIVATIZATION WITH IODOMETHANE-D(3) OR PFPA/HFIP IN HUMAN BLOOD AND URINE USING GC/MS (EI OR PCI MODE) [J].
ADERJAN, RE ;
SCHMITT, G ;
WU, M ;
MEYER, C .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) :51-55
[2]   CLINICAL-PHARMACOLOGY AND TOXICOLOGY OF COCAINE [J].
BENOWITZ, NL .
PHARMACOLOGY & TOXICOLOGY, 1993, 72 (01) :3-12
[3]   Determination of common drugs of abuse in body fluids using one isolation procedure and liquid chromatography atmospheric pressure chemical ionization mass spectrometry [J].
Bogusz, MJ ;
Maier, RD ;
Kruger, KD ;
Kohls, U .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1998, 22 (07) :549-558
[4]  
Brain P F, 1989, J Subst Abuse, V1, P431
[5]   GAS CHROMATOGRAPHY-CHEMICAL IONIZATION MASS-SPECTROMETRY OF COCAINE AND ITS METABOLITES IN BIOLOGICAL-FLUIDS [J].
CHINN, DM ;
CROUCH, DJ ;
PEAT, MA ;
FINKLE, BS ;
JENNISON, TA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (01) :37-42
[6]   The determination of cocaine, benzoylecgonine, and cocaethylene in small-volume oral fluid samples by liquid chromatography-quadrupole-time-of-flight mass spectrometry [J].
Clauwaert, K ;
Decalestecker, T ;
Mortier, K ;
Lambert, W ;
Deforce, D ;
Van Peteghem, C ;
Van Bocxlaer, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (08) :655-659
[7]   Liquid chromatographic determination of cocaine, benzoylecgonine, and cocaethylene in whole blood and serum samples with diode-array detection [J].
Clauwaert, KM ;
VanBocxlaer, JF ;
Lambert, WE ;
DeLeenheer, AP .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (07) :321-328
[8]   PHARMACOKINETICS AND PHARMACODYNAMICS OF COCAINE [J].
CONE, EJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (06) :459-478
[9]  
CONE EJ, 1994, CLIN CHEM, V40, P1299
[10]  
DASGUPTA A, 1995, J FORENSIC SCI, P511