Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral Components

被引:85
作者
Lombardi, Adolph V., Jr. [1 ,2 ,3 ,4 ]
Berend, Keith R. [1 ,2 ,4 ]
Mallory, Thomas H. [1 ,2 ]
Skeels, Michael D. [1 ,4 ]
Adams, Joanne B. [1 ]
机构
[1] Joint Implant Surg Inc, New Albany, OH 43054 USA
[2] Ohio State Univ, Dept Orthopaed, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[4] Mt Carmel Hlth Syst, New Albany, OH USA
关键词
TOTAL HIP-ARTHROPLASTY; TOTAL KNEE ARTHROPLASTY; 11-YEAR FOLLOW-UP; LONG-TERM; PERIPROSTHETIC FRACTURES; YOUNG-PATIENTS; WEAR DEBRIS; CEMENTLESS; PROSTHESIS; REPLACEMENT;
D O I
10.1007/s11999-008-0568-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tapered titanium porous plasma-sprayed components have performed well in primary THA. To confirm the literature at longer followup we retrospectively reviewed all 1639 patients who underwent 2000 THAs in which a specific porous femoral component was used. One hundred fourteen patients (134 hips) were lost to followup leaving a cohort of 1525 patients (1866 THAs). The component is a tapered titanium plasma spray-coated design that remained relatively unchanged since its first implantation except for circumferential proximal porous coating added in 1986 and an offset option added in 1999. Minimum followup was 24 months (average, 119 months; range, 24 to 275 months). To date there have been 39 femoral revisions for an implant survival of 98%. Using the Kaplan-Meier method, cumulative survival with any stem revision as the end point was 98.6% at 5 years, 98.4% at 10 years, 97.1% at 15 years, and 95.5% at 20 years. Using aseptic revision for failure of ingrowth as the endpoint, stem survival was 99.1%. Kaplan-Meier cumulative survival with aseptic revision for failure of ingrowth as the endpoint was 99.4% at 5 years, 99.3% at 10, 15 and 20 years. Harris hip pain and total scores improved. This titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of component revision for any reason or aseptic failure of ingrowth. Level of Evidence: Level IV, therapeutic study (case series). See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:146 / 154
页数:9
相关论文
共 69 条
[1]  
*AM AC ORTH SURG, OST HIP HIP JOINT RE
[2]   Tapered cementless femoral stem: Difficult to place in varus but performs well in those rare cases [J].
Berend, Keith R. ;
Mallory, Thomas H. ;
Lombardi, Adolph V., Jr. ;
Dodds, Kathleen L. ;
Adams, Joanne B. .
ORTHOPEDICS, 2007, 30 (04) :295-297
[3]   Cerclage wires or cables for the management of Intraoperative fracture associated with a cementless, tapered femoral prosthesis [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Chonko, DJ ;
Dodds, KL ;
Adams, JB .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :17-21
[4]   Cernentless double-tapered total hip arthroplasty in patients 75 years of age and older [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Dodds, KL ;
Adams, JB .
JOURNAL OF ARTHROPLASTY, 2004, 19 (03) :288-295
[5]  
BOBYN JD, 1995, CLIN ORTHOP RELAT R, P21
[6]  
BOBYN JD, 1994, CLIN ORTHOP RELAT R, P27
[7]  
Bourne RB, 2001, CLIN ORTHOP RELAT R, P112
[8]   OPTIMAL FIXATION FOR FEMORAL COMPONENTS - CEMENTED OR CEMENTLESS [J].
CALLAGHAN, JJ ;
MALLORY, TH .
JOURNAL OF ARTHROPLASTY, 1995, 10 (03) :401-404
[9]   The role of modularity in primary total hip arthroplasty [J].
Cameron, Hugh U. ;
Keppler, Louis ;
McTighe, Tim .
JOURNAL OF ARTHROPLASTY, 2006, 21 (04) :89-92
[10]   Primary total hip arthroplasty with use of the modular S-ROM prosthesis - Four to seven-year clinical and radiographic results [J].
Christie, MJ ;
DeBoer, DK ;
Trick, LW ;
Brothers, JC ;
Jones, RE ;
Vise, GT ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1707-1716